7.12. PROFILE SEAL INSTALLATION
Black Rubber Sealing Ring (Profile Seal) must be installed in the Guide Claw before pump is installed. Ring must
be installed with the large diameter lip inside the groove of the Guide Claw Flange.
CALL OUR TECHNICAL SUPPORT GROUP WITH ANY QUESTIONS REGARDING THE INSTALLATION OF
THIS EQUIPMENT.
7.13. SEAL PROBE INSTALLATION PROCEDURE
Mechanical Seal Leak Detection probe has been loose to protect from shipping damage. Please follow
this procedure to install the probe.
8)
Lay pump on its side with the plug on the seal chamber facing upwards as indicated.
9)
Unscrew the plug with the proper wrench, taking care not to damage the sealing surface.
10)
Verify that seal chamber oil level is within ¼" of the indicated value. Measurement is from oil level to the
top of hole. See IOM Manual for seal chamber oil volume, if required.
11)
Remove the new sealing gasket from package and install it onto the seal probe plug.
12)
Install the seal probe with gasket into the opening, taking care not to damage the cable. Then tighten the
seal probe with the proper wrench until snug. Do not overtighten. Once tight, verify the seal gasket is
properly seated and the cable is not pinched or twisted.
NOTE: At installation of the seal probe be careful not to bind the seal probe cord as it is being installed into
the pump.
13)
Lift pump into a vertical position and inspect for any leaks.
14)
Secure seal probe cable to pump body and power cable with tyraps before installing pump.