After Installing Vibrator

Checking shaft
rotation
Adjusting
eccentric weights
for 00–10 frame
Martin Engineering M3910-04/19
Read entire section before beginning work.
1. Remove cap screws, washers, and vibrator weight covers.
DO NOT run vibrator with eccentric weights removed.
Running vibrator with eccentric weights removed will damage
bearings.
When checking shaft rotation with weight cover removed,
keep hands away from swinging weights. Weights can crush
fingers.
2. Start vibrator for one second, then stop.
3. Observe direction of motor rotation. If motor is not rotating in correct
direction, lockout / tagout / blockout / testout energy source and reverse
rotation. To reverse rotation of three-phase vibrator, reverse any two of
the three power supply wires.
4. Replace weight cover, taking care not to pinch o-ring.
Table IV shows the force output for each weight configuration.
For the most efficient operation, vibrator eccentric weights
should be adjusted to the lowest force setting required to move
the material. This will increase vibrator life and reduce energy
costs.
14