Actuator Mounting; Field Coating Touch-Up - Greenheck Vektor-MH Installation, Operation And Maintenance Manual

Laboratory exhaust system
Table of Contents

Advertisement

Bypass Air Plenum (BAP) and
Isolation Damper Access and

Actuator Mounting

Depending on the configuration and intended operation
of the system supplied, every Vektor plenum section
may not have a weatherhood and bypass air damper.
Typically systems that include a fan which is on standby
will have one less weatherhood and BAP damper
assembly than plenum sections. Refer to submittal
drawings for additional information. The appropriate
guard / cover needs to be removed for installation,
inspection and maintenance.
For Vektor fans with weatherhood - Access to the BAP
damper and the isolation damper, actuator(s) (optional
from factory) and voltage transformer (optional from
factory) mounting location, is gained through the
removal of the weatherhood guard / cover. The isolation
damper assembly can be removed from its location by
sliding it through the opening.
For Vektor fans without a weatherhood - A guard / cover
is located on the side of the plenum section. Removal of
the guard / cover gains access to the damper linkages,
actuator (optional from factory) and transformer
(optional from factory). The entire isolation damper
assembly can be removed through this opening.
If the Vektor units were not supplied with optional
actuators, the dampers have an extended jackshaft for
field mounting a customer supplied actuator.
10
Laboratory Exhaust Systems
Field Coating Touch-Up Procedure
for Scratched Areas
Standard coating and color for the Vektor laboratory
exhaust system is Greenheck's LabCoat™. The dark
gray (041) procedure below details the correct method
for repairing minor scratches in the coating.
TOUCH-UP PAINT REPAIR KIT CONTENTS
• One pint of Kem Kromik primer
- including a technical data sheet
• One pint of industrial enamel (041 Dark Gray)
- including a technical data sheet
• Four disposable foam brushes
• One sheet sandpaper
• Repair procedure details
1. Scuff affected area to be repaired using medium
sandpaper (provided) or medium scotch brite pad.
Feather the edges.
2. Clean affected area to be touched up using an
alkaline based cleaner and rinse.
3. Apply Kem Kromik primer using 1 inch foam brush
(provided). Follow technical data sheet instructions.
4. Allow primer to dry a minimum of 2 1/2 hours before
top coating.
5. Apply topcoat with industrial enamel using 1 inch
foam brush (provided). Follow technical data sheets
instructions. Allow painted units to air-dry and cure
before putting into service. See enclosed Technical
Data sheets for detailed drying and cure schedules
at different temperatures.
To order additional coating repair kits please reference
Greenheck's part number HAZ2203 HI-PRO 041 GRAY
FIELD DAMAGE REPAIR kit. Please contact factory
with your fan's serial number for colors other than our