PARRY PGC6 Instructions Manual

Hide thumbs Also See for PGC6:

Advertisement

Quick Links

INSTRUCTION REF: IN173
ISSUE No.
2
DATE 17.12.09
Page 1 of 16
INSTRUCTIONS
MODEL: PGC6
SAFETY INSTRUCTIONS
INSTALLATION INSTRUCTIONS
OPERATION INSTRUCTIONS
MAINTENANCE INSTRUCTIONS
CONVERSION INSTRUCTIONS
TECHNICAL DATA
PARTS LIST
SPARES LIST
WARRENTY INFORMATION
Customer Information
Unit Code:
Serial Number:
Purchase Date:
www.parry.co.uk

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PGC6 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for PARRY PGC6

  • Page 1 INSTRUCTION REF: IN173 ISSUE No. DATE 17.12.09 Page 1 of 16 INSTRUCTIONS MODEL: PGC6 SAFETY INSTRUCTIONS INSTALLATION INSTRUCTIONS OPERATION INSTRUCTIONS MAINTENANCE INSTRUCTIONS CONVERSION INSTRUCTIONS TECHNICAL DATA PARTS LIST SPARES LIST WARRENTY INFORMATION Customer Information Unit Code: Serial Number: Purchase Date:...
  • Page 2 To avoid scratching the highly polished exterior surface of this equipment whilst in transit, the protective film on the exterior surfaces has NOT been removed. It is IMPORTANT that this protective film is peeled off before the equipment is used. www.parry.co.uk...
  • Page 3: Installation

    2. During installation provision must be provided for combustion air supply to the appliance, which enters the appliance through the base and rear of the appliance, this should not be blocked at any time. SEE TECHNICAL DETAILS. www.parry.co.uk...
  • Page 4 ISSUE No. DATE 17.12.09 Page 4 of 16 3. Appliances are designed to be installed on Parry Catering Equipment for stability, should they be fitted on any other surface they should be suitably secured, to prevent excessive movement. 4. Connection to the appliance is by ½” BSPT at the rear of the appliance.
  • Page 5 Its is recommended that Chargrills to run on full gas after ignition for 10 minutes, then adjust as necessary to obtain correct cooking temperature. To remove any residue use scraper several times a day after cooking. Scaling will result if this is not done. Empty the fat drawer and clean every day. www.parry.co.uk...
  • Page 6: Maintenance Instructions

    Check that the flame safety device is operating by shielding the probe from the burner flame until the device operates. Check that the spark ignites the gas. Thoroughly clean the grid and fat discharge chute. Lower the grid into position and refit front facia panel. www.parry.co.uk...
  • Page 7 Push the new thermocouple gently into the gas cock and tighten the nut. Do not over tighten. Fit the probe into the burner head bracket and tighten the screw. The probe should be adjacent to and level with the top of a burner port ’+’. www.parry.co.uk...
  • Page 8 Refit float rail assembly. Reconnect gas feed to injector and gas cock and tighten. Refit the thermocouple and tighten, do not over tighten. Reconnect gas supply and soundness test. Check flame failure device is operating. Refit fascia and lava rock and grid. www.parry.co.uk...
  • Page 9: Conversion Instructions

    This conversion must be carried out by a competent qualified person. Model Injector Code Butane G30 @28mbar INJECT119 11.2” W.G. Propane G31 @ 37mbar 14.8” W.G. Nat Gas G20 @ 20mbar 8” INJECT193 W.G. Nat Gas G25 @ 25mbar 10” W.G. www.parry.co.uk...
  • Page 10: Technical Details

    1.0 M³/HR 35.9 FT³/HR BUTANE 1.724 LB/HR 0.782 KG/HR PROPANE G31 1.75 LB/HR 0.794 KG/HR G25 @ 25mb 1.238 M³/HR 44.56 FT³/HR INJECTORS Natural G20 = INJECT193 Butane G30 = INJECT119 Propane G31 = INJECT119 G25 @ 25mb = INJECT193 www.parry.co.uk...
  • Page 11 8) SPARK GENERATOR x 2 BRACKET01 9) SADDLE BRACKET KNOBTYPEF 10) GAS COCK KNOB x 2 GRIDAERAT 11) AERATOR x 2 FLUECOVER 12) FLUECOVER 13) LOW RATE ADJUSTER INJECT193 14) INJECTOR x 2 RAILPLATE 15) FLOAT RAIL MOUNTING PLATE www.parry.co.uk...
  • Page 12 INSTRUCTION REF: IN173 ISSUE No. DATE 17.12.09 Page 12 of 16 www.parry.co.uk...
  • Page 13: Spares List

    INJECT 119 Injector LPG CABLHT500 Ignition HT Lead LAVAROCKI Bag of lava rock 2kg CHARGERTOP Top Grid MESH TRAY Mesh Lava Rock Tray TUBES2HOB Float rail BRACKET01 Saddle bracket PGC6 FLUE COVER Flue cover PGC6 FAT DRAWER Fat drawer www.parry.co.uk...
  • Page 14  Please ensure you have read the section not covered under warranty to avoid any unnecessary warranty charges.  If the problem with the machine can not be resolved please contact the company that supplied you the machine. (SERVICE CALLS CAN NOT BE PLACED DIRECT WITH PARRY) www.parry.co.uk...
  • Page 15: Not Covered Under Warranty

    6 burner cooker.  Excessive carbon build up on griddle plates.  Over use of lava rock on the chargrills recommended use by Parry 2kg only.  Faulty electrics – eg, customers plug socket, plug, wiring, junction box fault, wrong fuse.
  • Page 16 Failure to pay any warranty charges will result in the customers warranty been put on hold until the bill has been settled. Any issues regarding the raised charges should be put in writing to our warranty department for further investigation. Parry Group Ltd Town End Road Draycott Derby...

Table of Contents