Summary of Contents for PARRY US9

  • Page 1 Instruction Manual Gas Salamander US9/US9P...
  • Page 3: Table Of Contents

    Service Information........................13 Exploded View ........................... 14 Parts List ..........................15-16 Warranty Information ........................ 17 Disposal & Recycling ......................... 18 Parry Catering Equipment (Midlands) Ltd, Town End Road, Draycott, Derby, DE72 3PT. Sales Tel: 01332 875544 Parry-British Built for Purpose IN153-5...
  • Page 4: Product Overview

    Product Overview Perfect for cooking fish, steaks or melting cheese, the Parry US9/US9P gas salamander wall grill – constructed from high grade stainless steel – is powerful and durable. The adjustable flame ensures that temperature regulation is responsive. The independent controls allow...
  • Page 5: Safety Instructions

    To avoid scratching the highly polished exterior surface of this equipment whilst in transit, the protective film on the exterior surfaces has NOT been removed. It is IMPORTANT that this protective film is peeled off before the equipment is used. Parry-British Built for Purpose IN153-5...
  • Page 6: Installation Instructions

    The appliance must be fitted securely on a non-combustible shelf or surface. Parry sells a wall shelf, bench stand and floor stand to accompany these units It is recommended that the appliance be sited below a ventilating hood preferably of the extractor type incorporating a grease filter.
  • Page 7 All units should have a restraining cable fitted preventing the unit from being pulled away from the wall and causing the gas hose to become disconnected accidentally. Parry-British Built for Purpose IN153-5...
  • Page 8: Operating Instructions

    TO LIGHT BURNER:- The US9 Salamander has two pairs of burners which can be controlled independently of one another with two sets of controls mounted on the left and right of the front of the machine.
  • Page 9: Cleaning Instructions

    The stainless outer panels require a wipe down with warm soapy water. Stainless steel cleaners maybe used and cleaning instructions on the product must be adhered Never clean the unit with water jets. DO NOT USE SCOURING PADS. Parry-British Built for Purpose IN153-5...
  • Page 10: Maintenance Instructions

    Maintenance and service must only be undertaken by a qualified electrician. Parry Catering provides a complete after-sales service by offering the sales of spare parts directly to customers. Buying spares straight from the manufacturer allows customer to experience exceptional value and speedy delivery on all spare parts.
  • Page 11 Reassemble in reverse order. Check for gas soundness and correct operation of flame failure unit. Refit side panel and top cover. PLEASE NOTE: IF THE BURNER PLAQUES ARE CRACKED, THEY WILL NOT BE COVERED BY WARRANTY Parry-British Built for Purpose IN153-5...
  • Page 12: Conversion Instructions

    Remove pilot injector and replace with NAT injector Replace the existing labels with NAT labels provided. Re-assemble in reverse order Connect to gas, and soundness test Gases Burner Injector Plot Injector Natural G20 Propane G31 Parry-British Built for Purpose IN153-5...
  • Page 13: Technical Information

    2.689 Kw/ 9,175 BTU 5.378 Kw/ 18,351 BTU Gas Rate Gas Rate Imperial Metric Natural G20 16.6 ft³/hr 0.0.47 m³/hr Propane G31 0.463 lb/hr 0.11 m³/hr Injector Sizes Gases Burner Injector Plot Injector Natural G20 Propane G31 Parry-British Built for Purpose IN153-5...
  • Page 14: Fault Finding

    Contact distributor for an Pilot will light but not stay lit Possible loose thermocouple engineer Contact distributor for an Possible faulty thermocouple engineer Contact distributor for an Crack in plaque on burner engineer Parry-British Built for Purpose IN153-5...
  • Page 15: Service Information

    This appliance should be routinely serviced to prolong its lifetime. Parry recommends that the appliance is serviced every 12 months by a Parry authorised engineer. Failure to service your product within the initial 12 month warranty period will cause the 24 month warranty to become void.
  • Page 16: Exploded View

    Exploded View Parry-British Built for Purpose IN153-5...
  • Page 17: Parts List

    Pilot Injector Pilot injectors Only (Pilot Injector Only) PINJ76371 (Per pilot) (LPG) PINJ76378 (Per pilot) (NAT) Pilot Pipe Bundy Tube Assembly ULTPWUS9 Burner Injector INJECT099 (x4) (LPG) INJECT150 (x4) (NAT) 8mm Equal Tee Compression FRYERTEE8 Fitting Parry-British Built for Purpose IN153-5...
  • Page 18 Gas Valve CW Ignitor and HT Lead GWBGASVALVE *Inner Base Pressure Nipple PRESSNIPP Gas Manifold US9FLOATRAILUS9 *Exterior Base Bundy Tube Assembly ULTPWUS9 8mm – 1/4" BSP Taper COUPLE8MM Compression Coupling *Float Rail Bracket M6 S/S Spacer M6SPACER *Fat Tray *Metalwork Components Parry-British Built for Purpose IN153-5...
  • Page 19: Warranty Information

    Parry and not the sale or installation date of the equipment. Please ensure you have referred to the manufacturer’s instruction before placing a warranty...
  • Page 20: Disposal & Recycling

    Disposal & Recycling The packaging should be disposed of in accordance with the regulations in force. Parry-British Built for Purpose IN153-5...