Installation and Operation Instruction Manual CEP-081A, 101A, 121A PREPARATION Preparation control panel upper air filter (behind the grille) handle (both sides) horizontal upper air intake louver blade drain outlet air outlet lower air filter lower air intake power plug socket...
Installation and Operation Instruction Manual CEP-081A, 101A, 121A SAFETY PRECAUTIONS Safety Precautions Please read through these instructions before you start the installation process. Improper installation can cause damage -DO NOT install your air conditioner in a wet room such as to the unit, your personal property, and also poses a a bathroom or laundry room.
Installation and Operation Instruction Manual CEP-081A, 101A, 121A CAUTIONS Cautions -This appliance can be used by children aged from 8 years and above and those with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
Installation and Operation Instruction Manual CEP-081A, 101A, 121A INSTALLATION Installation Note About Fluorinated Gasses Choosing The Right Location - This air-conditioning unit is a hermetically sealed unit that contains fluorinated gasses. For specific information on the type of gas and the amount, please refer to the relevant label on the unit itself.
Page 8
Installation and Operation Instruction Manual CEP-081A, 101A, 121A INSTALLATION Installation Tools Needed Window Installation Kit -Medium Philips screwdriver; -Tape measure or ruler; -Knife or scissors; -Saw (optional, to shorten window adaptor for narrow windows) Step One: Preparing the Exhaust Hose assembly...
Page 9
Installation and Operation Instruction Manual CEP-081A, 101A, 121A INSTALLATION Installation Note: Once the Exhaust Hose assembly and Adjustable Window Slider are prepared, choose from one of the following two installation methods. Type 1: Hung Window Installation Foam seal B (Adhesive type-shorter)
Page 10
Installation and Operation Instruction Manual CEP-081A, 101A, 121A INSTALLATION Installation Foam seal C (Non-adhesive type) Security Bracket 2 Screws Cut the non-adhesive foam If desired, install the security seal C strip to match the bracket with 2 screws as shown.
Installation and Operation Instruction Manual CEP-081A, 101A, 121A OPERATION Operation (3s activate ion) Swing button(optional) Timer button Mode button (Applicable to the models with auto Used to initiate the AUTO ON Selects the appropriate operating mode. Each swing feature only)
Page 12
Installation and Operation Instruction Manual CEP-081A, 101A, 121A OPERATION Operation LED display AUTO operation -When you set the air conditioner in AUTO mode, it will automatically select cooling, Shows the set temperature in °C or °F and the Auto-timersettings. heating(cooling only models without), or fan only operation depending on what temperature While on DRY and FAN modes, it shows the room temperature.
Page 13
Installation and Operation Instruction Manual CEP-081A, 101A, 121A OPERATION Operation Other features -During heating pump mode, remove the lower drain plug from the back of the unit, install the FOLLOW ME/TEMP SENSING feature(optional) drain connector(5/8" universal female) with 3/4" NOTE:This feature can be activated from the remote control ONLY. The remote control hose (locally purchased).
Installation and Operation Instruction Manual CEP-081A, 101A, 121A MAINTENANCE Maintenance Safety Precautions Clean the Unit Clean the unit using a damp, lint-free cloth and mild detergent. Dry -Always unplug the unit before cleaning or servicing. the unit with a dry, lint-free cloth.
Installation and Operation Instruction Manual CEP-081A, 101A, 121A FAULT DIAGNOSIS Faults Diagnosis Please check the following form before asking for maintenance: Problem Troubleshooting Possible Cause The Water Collection Tray is full. Turn off the unit, drain the water P1 Error Code...
Installation and Operation Instruction Manual CEP-081A, 101A, 121A DESIGN AND COMPLIANCE NOTES Design and Compliance Notes Design Notice In order to ensure the optimal performance of our products, the design specifications of the unit and remote control are subject to change without prior notice.
Installation and Operation Instruction Manual CEP-081A, 101A, 121A UNIT DISPOSAL Sociable Remark DISPOSAL: Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary. It is prohibited to dispose of this appliance in domestic household waste.
Page 18
Installation and Operation Instruction Manual CEP-081A, 101A, 121A THIS PAGE INTENTIONALLY LEFT BLANK www.coastair-ac.com...
Page 19
Installation and Operation Instruction Manual CEP-081A, 101A, 121A LIMITED EXPRESS WARRANTY REMEDY PROVIDED BY THE LIMITED EXPRESS WARRANTY Congratulations on purchasing your new HVAC equipment. It’s been designed for long life and reliable service, and is backed The sole remedy under the Limited Warranty is replacement of the by one of the strongest warranties in the industry.
Need help?
Do you have a question about the CEP-081A and is the answer not in the manual?
Questions and answers
Getting P1 error code. Water tray filling up quickly and unit running hot. What do I need to do.
getting P1 code. the water tray is filling up very quickly and unit seems to be running very hot. What else do I need to do?