Observe the deceleration of the car. If it is too long, turn No. 3 ‘out’ ¼ turn; if it is too short, turn No. 3 ‘in’ ¼ turn. Repeat until deceleration is satisfactory. Deceleration time should be about 2.5 s. BLAIN HYDRAULICS · Pfa enstrasse 1 · D-74078 Heilbronn · Tel. +49 7131 28210 · Fax +49 7131 282199 · www.blain.de · info...
Page 7
K must be backed off until the car just begins to descend, then backed off a further half turn to ensure that with cold oil, the car can be lowered as required. BLAIN HYDRAULICS · Pfa enstrasse 1 · D-74078 Heilbronn · Tel. +49 7131 28210 · Fax +49 7131 282199 · www.blain.de · info...
Page 9
S completely, then turn out S for 1½ turns; turn in adj. 2,3 & 5 completely, turn out adj. 3 & 5 for 2½ turns and turn out adj. 2 for EV ¾”: 1½ turns and for EV 1½” - 2½”: 2½ turns. BLAIN HYDRAULICS · Pfa enstrasse 1 · D-74078 Heilbronn · Tel. +49 7131 28210 · Fax +49 7131 282199 · www.blain.de · info...
Page 10
8 for 1 turn; for EV1½” - 2½”: turn adj. 6 for 2 to 2½ turns out and adj. 8 for 1½ turns out. BLAIN HYDRAULICS · Pfa enstrasse 1 · D-74078 Heilbronn · Tel. +49 7131 28210 · Fax +49 7131 282199 · www.blain.de · info...
To order EV: Size (inch), valve type, state pump fl ow, empty car pressure (or fl ow guide size) and solenoid voltage. Example order: 2"EV100, 380l/min, 18bar (empty), 110 AC or 2"EV100/4/110AC apr 16 Designer and Manufacturer of the highest Blain Hydraulics GmbH Tel. +49 7131 28210 quality control valves & safety components Pfa enstrasse 1 Fax +49 7131 282199 BLAIN HYDRAULICS ·...
Page 13
A broken spring 9 would cause the down levelling speed to be slower. No danger to passengers would arise as a consequence. BLAIN HYDRAULICS · Pfa enstrasse 1 · D-74078 Heilbronn · Tel. +49 7131 28210 · Fax +49 7131 282199 · www.blain.de · info...
Page 16
If the coil gets too hot, the coil has to be mounted onto the solenoid and the following adjustments have to be carried out on normal travels from floor to floor. Standard settings: Adjustments 7 & 9, screw heads level with the hexagon heads. BLAIN HYDRAULICS · Pfa enstrasse 1 · D-74078 Heilbronn · Tel. +49 7131 28210 · Fax +49 7131 282199 · www.blain.de · info...
4. In the case of Blain EV valves, see page 10 EV and 16 KV indicating where valve down leakage can occur. BLAIN HYDRAULICS · Pfa enstrasse 1 · D-74078 Heilbronn · Tel. +49 7131 28210 · Fax +49 7131 282199 · www.blain.de · info...
Need help?
Do you have a question about the EV Series and is the answer not in the manual?
Questions and answers