3 + 4
10 Overheating of Power Unit. System Leakage
12 Flow-Pressure-Tables (metric), EV 100 Size Selection
Tel. +49 7131 2821-0 • Fax +49 7131 48 52 16 • www.blain.de • info@blain.de
Oct 02
BLAIN HYDRAULICS GmbH • Boellinger Hoefe • D-74078 Heilbronn • Tel. +49 7131 28 21-0 • Fax +49 7131 485216 • www.blain.de • info@blain.de
Printed in Germany
Service Manual
Elevator Valve EV 100
1
3/4“ Cross Section Diagrams of Valve
2
1 1/2“ - 2“ Section Diagrams of Valve
5
6
EV Trouble Shooting, Up Travel
7
EV Trouble Shooting, Down Travel
8
KS Slack Rope Valve Purpose and Adjustment
9
Down Leveling Adj. 9, Replacement
11 Switches, Slow Down Distances
13 Flow-Pressure-Tables (USA)
Blain Hydraulics GmbH
Pfaffenstr. 1 • Boellinger Hoefe • D-74078 Heilbronn • Germany
Manufacturer of the Highest Quality:
Control Valves for Elevators
Tank Heaters - Hand Pumps - Pipe Rupture Valves - Ball Valves
EN ISO 9001

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EV 100 and is the answer not in the manual?

Questions and answers

Summary of Contents for Blain Hydraulics EV 100

  • Page 1 Tank Heaters - Hand Pumps - Pipe Rupture Valves - Ball Valves Oct 02 BLAIN HYDRAULICS GmbH • Boellinger Hoefe • D-74078 Heilbronn • Tel. +49 7131 28 21-0 • Fax +49 7131 485216 • www.blain.de • info@blain.de Printed in Germany...
  • Page 2: Technical Data

    Fax: +49 7131 485216 • Fax 01149 7131 485216 E-Mail: info@blain.de URL: http://www.blain.de Oct 02 BLAIN HYDRAULICS GmbH • Boellinger Hoefe • D-74078 Heilbronn • Tel. +49 7131 28 21-0 • Fax +49 7131 485216 • www.blain.de • info@blain.de Printed in Germany...
  • Page 3 Soupape descente Válvula de bajada Vertical Descente petite vitesse Bajada lentísima Section Oct 02 BLAIN HYDRAULICS GmbH • Boellinger Hoefe • D-74078 Heilbronn • Tel. +49 7131 28 21-0 • Fax +49 7131 485216 • www.blain.de • info@blain.de Printed in Germany...
  • Page 4 Cylindro Soupape descente Válvula de bajada Descente petite vitesse Bajada lentísima Oct 02 BLAIN HYDRAULICS GmbH • Boellinger Hoefe • D-74078 Heilbronn • Tel. +49 7131 28 21-0 • Fax +49 7131 485216 • www.blain.de • info@blain.de Printed in Germany...
  • Page 5 No. 4 ‘in’ until the speed is as required. If the speed is too slow, turn No. 4 ‘out’. Recommended speed 6 cm/sec. Oct 02 BLAIN HYDRAULICS GmbH • Boellinger Hoefe • D-74078 Heilbronn • Tel. +49 7131 28 21-0 • Fax +49 7131 485216 • www.blain.de • info@blain.de Printed in Germany...
  • Page 6 Oct 02 BLAIN HYDRAULICS GmbH • Boellinger Hoefe • D-74078 Heilbronn • Tel. +49 7131 28 21-0 • Fax +49 7131 485216 • www.blain.de • info@blain.de Printed in Germany...
  • Page 7 EV 100 1½", 2", 2½" Vertical Section Horizontal Sections KS Option Oct 02 BLAIN HYDRAULICS GmbH • Boellinger Hoefe • D-74078 Heilbronn • Tel. +49 7131 28 21-0 • Fax +49 7131 485216 • www.blain.de • info@blain.de Printed in Germany...
  • Page 8 Releveling may also occur as hot oil cools down and contracts. Oct 02 BLAIN HYDRAULICS GmbH • Boellinger Hoefe • D-74078 Heilbronn • Tel. +49 7131 28 21-0 • Fax +49 7131 485216 • www.blain.de • info@blain.de Printed in Germany...
  • Page 9 Consider oil cooler if hot oil is a problem. Contraction of oil during cooling especially from above 35°C. Oct 02 BLAIN HYDRAULICS GmbH • Boellinger Hoefe • D-74078 Heilbronn • Tel. +49 7131 28 21-0 • Fax +49 7131 485216 • www.blain.de • info@blain.de Printed in Germany...
  • Page 10 0-Ring K 3 Lock Screw K 2 Adjustment Screw K Adjustment Oct 02 BLAIN HYDRAULICS GmbH • Boellinger Hoefe • D-74078 Heilbronn • Tel. +49 7131 28 21-0 • Fax +49 7131 485216 • www.blain.de • info@blain.de Printed in Germany...
  • Page 11 A broken spring 9 would cause the down leveling speed to be slower. No danger to passengers would arise as a consequence. Oct 02 BLAIN HYDRAULICS GmbH • Boellinger Hoefe • D-74078 Heilbronn • Tel. +49 7131 28 21-0 • Fax +49 7131 485216 • www.blain.de • info@blain.de Printed in Germany...
  • Page 12 4. In the case of Blain EV valves, see page 6 indicating where valve down leakage can occur. Oct 02 BLAIN HYDRAULICS GmbH • Boellinger Hoefe • D-74078 Heilbronn • Tel. +49 7131 28 21-0 • Fax +49 7131 485216 • www.blain.de • info@blain.de Printed in Germany...
  • Page 13 Oct 02 BLAIN HYDRAULICS GmbH • Boellinger Hoefe • D-74078 Heilbronn • Tel. +49 7131 28 21-0 • Fax +49 7131 485216 • www.blain.de • info@blain.de Printed in Germany...
  • Page 14 100 120 140 160 180 200 1000 1200 1400 1600 l/min. l/min. l/min. Oct 02 BLAIN HYDRAULICS GmbH • Boellinger Hoefe • D-74078 Heilbronn • Tel. +49 7131 28 21-0 • Fax +49 7131 485216 • www.blain.de • info@blain.de Printed in Germany...
  • Page 15 55,8 67,0 78,2 89,3 101,5 111,7 134,0 156,3 178,6 201,0 223,3 Oct 02 BLAIN HYDRAULICS GmbH • Boellinger Hoefe • D-74078 Heilbronn • Tel. +49 7131 28 21-0 • Fax +49 7131 485216 • www.blain.de • info@blain.de Printed in Germany...