PROCEDURE
1. Wait until the end of defrost cycle then disconnect
power from the unit
2. Close water tap on the water supply line
NOTE. Be sure that no other equipment in use can
suffer of the turn OFF of water
3. Remove all ice from the bin. Either save it in a
sanitary container or discard it. If routine sanitizing is
due, the ice machine should be switched off during
evening closing procedures to minimize waste
during next morning sanitizing procedures.
4. Remove the front panel.
5. Gently remove from upper plastic hooks the O rings
securing curtain/deflector in front of the evaporator.
6. Carefully withdraw curtain/deflector by gently lifting
the upper hooks. Unnecessary force can break the
plastic hooks.