Dakota / Kansas / Inver / Copenhagen
Model: DKT20 / KNS20 / INV20 / COP20
IMPORTANT: THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE
Installation
- see Fig. 1 & 3.
Your electric fire is designed to be used in a fireplace opening or placed
against a wall anywhere in the room.
When installing this appliance in an existing fireplace opening, we
recommend that an open chimney or flue is blocked off. We recommend
that non-flammable materials are used to block off the chimney flue. This
procedure is important for the efficient operation of the heating unit and
will also reduce heat loss up the chimney.
At the rear of the fire, two adjustable feet are provided for levelling the
fire where the fire is being installed on an uneven surface. You can
adjust the foot by removing the two screws and refitting the foot in the
required position.
The fire is supplied with screws and rawl plugs to provide extra stability
to prevent it from accidentally being knocked over. The rawl plug supplied
is suitable for use in block walls (other wall types may need alternative
rawl plugs).
To place the appliance flush to a wall please follow these instructions:
Drill holes using a 6mm drill as illustrated in Fig.1. Insert plugs and screws.
The plug supplied is suitable for use in block walls (special fasteners
are required on stud walls). Do not fully tighten screws, leave the head
of the screw at least 10mm away from the surface. Place the keyhole
slots on the fire over the screws and lower into position.
To gain access to the fixing holes in the base, remove the fret and fuel
effect from the fire. Remove the fret by lifting it up and then pulling it out
from the fire, remove the 3 screws holding the fuel bed in place and slide
it away from the fire.(See Fig. 3, shown Kansas Fret). Using the screws
provide screw the fire in place as shown in Fig. 1. Carefully refit the fret
and fuel effect in reverse of the removal procedure as described above.
The other models fret removes in the same manner as the Kansas fret.
Manual Controls - see Fig. 2
Three switches provide a choice of heat setting. Each switch is activated
when the bottom half of the switch is pushed in.
Switch 1 Controls the electricity supply to the heater.
Note: This switch must be in the ON position for the heater
to operate with or without heat.
Switch 2 Provides 950 W heat output.
Switch 3 Provides 1900 W output when used in conjunction with switch2
Thermostat
In order to maintain a certain room temperature, set the thermostat
knob to 'max.'. Operate the appliance at full power until the required
room temperature is reached. Turn back the thermostat knob until the
appliance switches off. This temperature will be kept almost constant by
the thermostat switching on and off automatically.Please note that the
appliance will only operate when the thermostat setting is higher then
the room temperature.
Thermal Safety Cut-out
A thermal safety cut-out is incorporated in the heater to prevent damage
due to overheating. This can happen if the heat outlet was restricted
in any way. The heater will switch on once the obstruction has been
removed and the heater has cooled. If the cut-out continues to operate
intermittently, the heater should be switched off and a service agent
contacted.
Dimplex
Millbrook House
GrangeDrive
HedgeEnd
Southampton
Hampshire.SO30 2DF
[c] GDC Group Ltd,
All rights reserved. Material contained in this publication may not be reproduced in whole or in part, without prior permission in writing of Dimplex.
A division of GDC Group Ltd,
Maintenance
WARNING: ALWAYS DISCONNECT FROM THE POWER SUPPLY
BEFORE ATTEMPTING ANY MAINTENANCE.
Light Emitting Diode
This fire is fitted with LED (Light Emitting Diode) lamps in place of
conventional bulbs . These generate the same light levels as conventional
bulbs, but use a fraction of the energy consumed. These LED lamps
are maintenance – free and should not require replacing during the life
of the product.
Cleaning
WARNING – ALWAYS DISCONNECT FROM THE POWER SUPPLY
BEFORE CLEANING THE HEATER.
For general cleaning use a soft clean duster – never use abrasive
cleaners. The glass viewing screen should be cleaned carefully with a
soft cloth. DO NOT use proprietary glass cleaners.
To remove any accumulation of dust or fluff the soft brush attachment of
a vacuum cleaner should occasionally be used to clean the outlet grille
of the fan heater.
Recycling
For electrical products sold within the European
Community.
At the end of the electrical products useful life it should
not be disposed of with household waste. Please
recycle where facilities exist. Check with your Local
Authority or retailer for recycling advice in your country.
After Sales Service
Your product is guaranteed for one year from the date of purchase.
Within this period, we undertake to repair or exchange this product free
of charge (excluding lamps & subject to availability) provided it has been
installed and operated in accordance with these instructions.
Your rights under this guarantee are additional to your statutory rights,
which in turn are not affected by this guarantee.
Should you require after sales information or assistance with this product
please go to www.dimplex.co.uk where you will find our self help guide
by clicking on "After Sales" or ring our helpdesk on 0844 879 3588 (UK)
or 01 842 4833 (R.O.I.) .
Spare parts are also available on the website
www.dimplex.co.uk
Please retain your receipt as proof of purchase.
TEL: 0844 879 3588
FAX: 0844 879 3583
WEBSITE: www.dimplex.co.uk
Republic of Ireland
Tel.01 8424833
UK

Advertisement

loading

This manual is also suitable for:

Dakota seriesDakota dkt20Inver seriesCopenhagen seriesDakota dkt20blKansas kns20 ... Show all