Huawei AR502 Series Quick Start Manual page 7

Table of Contents

Advertisement

AR502EG-L-PD does not involve installation inside the enclosure assembly box. The procedures for
NOTE
wall-mounted and pole-mounted installation are similar to those for the IP65 enclosure assembly
box. The following describes the installation procedures for the IP65 enclosure assembly box.
Procedure
1
Put the IP65 enclosure assembly box upside down on a table and loosen screws using the Phillips
screwdriver.
1
2
Rotate the PG connector of the IP65 enclosure assembly box anticlockwise to remove it using the torque
wrench and remove the box cover.
3
Use the Phillips screwdriver and four M3x7 bolts to install the router (with the side where the SIM card is
installed facing up) in the IP65 enclosure assembly box.
4
Connect the ZigBee antenna, USB cable, power cable, and two LTE antennas in the IP65 enclosure
assembly box to the router.
5
Pull the power cable out from the PG interface of the IP65 enclosure assembly box.
6
Use the Phillips torque screwdriver to tighten the screws with a torque of 1.3 N·m to put the cover back to
the IP65 enclosure assembly box.
2
4
3
5
6
6

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents