Rheem 64DV Troubleshooting Manual page 72

For mid & high efficiency platforms. tankless gas
Hide thumbs Also See for 64DV:
Table of Contents

Advertisement

S V C 8 2 0 ( P ) P o c k e t M a n u a l P a g e
While unit is attempting to
ignite:
Check DC volts across
#1 wire (Red) and #2 wire
(Black) on connector R :
1.5 – 14 DC Volts
While unit is attempting to
ignite:
Check DC volts across Red
and Black wires at PGFR:
1.5 – 14 DC Volts
Make sure Black & Red wires
are properly connected to
PGFR. Operate unit.
IF 52 - Error Code appears:
Replace gas control valve.
RED & BLACK
WIRES
Remove & reinsert R .
Operate unit.
NO
If 52 – Error Code appears:
Replace control board.
Replace wiring harness for
connector R on control
NO
71