Rheem 64DV Troubleshooting Manual page 120

For mid & high efficiency platforms. tankless gas
Hide thumbs Also See for 64DV:
Table of Contents

Advertisement

S V C 8 2 0 ( P ) P o c k e t M a n u a l P a g e
Blower Motor
*Move control board bracket out of way to access WHITE Molex for
inlet thermistor (follow instructions in Section 1).
* To REPLACE thermistor ONLY: Separate WHITE Molex (circled in
green). Thermistor is attached to female end of Molex (white wire).
*Remove Water Bypass & Water Volume valves
(follow instructions in Section 7).
*Remove single screw for the inlet thermistor.
*Remove Inlet thermistor (O-ring should remain in thermistor well).
1
Water Volume Control Valve
119
2
119