Cisco IMC REST API Examples
"Language":"en",
"RegistryPrefix":"",
"Messages":{
"F0381":{
},
"F0395":{
},
"F0176":{
},
},
"F0424":{
}
},
"Id":"Message Registry",
"Description":"This registry defines the Fault messages for Redfish"
}

Enabling an Event Service

Request:
"Oem":{
"MessageId":12
},
"Message":"",
"NumberOfArgs":0,
"Severity":"minor",
"Resolution":"Check power supply status",
"Description":"Power Supply temperature is upper non critical"
"Oem":{
"MessageId":25
},
"Message":"",
"NumberOfArgs":0,
"Severity":"minor",
"Resolution":"Check the air intake to the server",
"Description":"Fan speed for fan-x is lower non critical"
"Oem":{
"MessageId":10
},
"Message":"",
"NumberOfArgs":0,
"Severity":"major",
"Resolution":"Check Cooling",
"Description":"Processor Thermal threshold has crossed
upper critical threshold"
.
.
.
.
"Message":"",
"NumberOfArgs":0,
"Severity":"major",
"Resolution":"Check the air intake to the server",
"Description":"Fan speed for fan-x is lower critical"
"Oem":{
"MessageId":20
},
"Message":"",
"NumberOfArgs":0,
"Severity":"major",
"Resolution":"Replace Battery",
"Description":"Battery voltage level is lower critical"