Quickstart
This is a secure Z-Wave Device for Europe. To run this device please insert fresh 1 * CR14250 batteries. Please make sure the internal battery is fully
charged.
Pressing the "Z-Wave button" for one second adds (includes) and removes (excludes) the device from/to the Z-Wave network.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
(For more information about frequency regulations please refer to
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and
every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is
not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified
Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this
device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level
of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.

Product Description

This product combines a certified carbon monoxide detector with a plug-in Z-Wave module to form a wirelessly reporting carbon monoxide sensor. The high-end
carbon monoxide detector offers a test button conveniently accessible even with a broom stick when mounted on the ceiling. Three colored LEDs on the device
indicate Alarm, Error and Battery Level. The Alarm conditions is reported wirelessly using Z-Wave. Beside the Carbon monoxide danger alarm the device will also
report a tamper alarm if the sensor is removed from the mounting base. The device is a secure Z-Wave Plus device and can be used in one wireless Z-Wave
network with other certified devices regardless of origin and brand.

Prepare for Installation / Reset

Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do
this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended
to use the primary controller of the previous network to make sure the very device is excluded properly from this network.

Reset to factory default

This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
Keep The Z-Wave Button pressed for 10 seconds. the LED wil start flashing after 5 seconds

Safety Warning for Batteries

The product contains batteries. Please remove the batteries when the device is not used. Do not mix batteries of different charging level or different brands.

Installation

Please refer to the installation guide of the carbon sensor attached for information about how and where the carbon monoxide sensor should be installed. Please
note that the carbon monoxide sensor will also work stand-alone even if no Z-Wave network is present
the frequency coverage overview at Sigma Designs Website
).

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the POPE004407 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Popp POPE004407

  • Page 1 Z-Wave CO Detector SKU: POPE004407 Quickstart This is a secure Z-Wave Device for Europe. To run this device please insert fresh 1 * CR14250 batteries. Please make sure the internal battery is fully charged. Pressing the "Z-Wave button" for one second adds (includes) and removes (excludes) the device from/to the Z-Wave network.
  • Page 2 1. The first step is to mount the mounting base on the desired place in the home using screws. 2. Remove the battery isolation strip from the wireless module. The red LED will start blinking. 3. Include the sensor into your existing Z-Wave based smart home network using the Z-Wave button. 4.
  • Page 3 • CO Danger Detected (this message will also be issued when the test button is pressed) • Low Battery Alarm (when the battery of the wireless modules goes low) • Tamper Detected (ON, when the CO detector head is removed from the base; OFF, when the detector head is mounted to the base) •...
  • Page 4 The reproduction and distribution of the documentation and software supplied with this product and the use of its contents is subject to written authorization from Popp & Co. We reserve the right to make any alterations that arise as the result of technical...
  • Page 5 Popp hereby declares this device complies with the essential requirements and other relevant prescriptions of Directive 1999/5/EC R&TTE. The complete CE declaration can be found on: www.popp.eu/ce. All questions regarding this declaration of conformity can be directed to the following address: Popp c/o BID GmbH, Neuer Wall 63, 20148 Hamburg, Germany Disposal Guidelines Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities.

Table of Contents