This is a secure Alarm Sensor for Europe. To run this device please insert fresh 1 * 1/2 AA batteries. Please make sure the internal battery is fully
charged. Tripple clicking the tamper button includes (adds) and excludes (removes) the device. A click on the tamper witch will wake up the device.
The device supports the Security S2 framework with unauthenticated network keys. Please follow the instructions on the central controller when
including. The device also supports Smartstart. Please scan the QR code on the outlet cover of the device and your controller will add the device
automatically when powered up.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart
section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-way communication)
and every mains powered node can act as a repeater for other nodes (meshed network) in case the
receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-
Wave device regardless of brand and origin as long as both are suited for the same frequency
range.
If a device supports secure communication it will communicate with other devices secure as long as
this device provides the same or a higher level of security. Otherwise it will automatically turn into a
lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.

Product Description

This device measures the three air quality parameters temperature, humidity and dew point an reports them to a central controller. Beside this, the device
can directly control groups of other Z-Wave devices on over- and undershooting a set temperature and/or humidity parameter. This can be used to
establish control loops for temperature and humidity. The device wakes up every 4 minutes to measure the values and it will send unsolicited reports when
values change. Additionally, the device will report all values on request.
The mold detector is actively monitoring the danger of mold in a room based on the temperature and humidity and will issue alarm warnings
when critical air conditions met. Wireless Alarm and red and a green blinking LED will indicate a mold condition. This local LED warning function is also
available when the device is not included in any Z-Wave network and works stand alone.

Prepare for Installation / Reset

Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You
can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is
recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.

Reset to factory default

This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is
inoperable.
Once Cover is removed and tamper switch is tripped, push the tamper for 5 seconds until red LED blinks. Then release tamper and push it again for 5
seconds until LED blinks.

Safety Warning for Batteries

The product contains batteries. Please remove the batteries when the device is not used. Do not mix batteries of different charging level or different
brands.

Installation

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the POPE701202 and is the answer not in the manual?

Questions and answers

Summary of Contents for Popp POPE701202

  • Page 1 Popp Mold detector SKU: POPE701202 Quickstart This is a secure Alarm Sensor for Europe. To run this device please insert fresh 1 * 1/2 AA batteries. Please make sure the internal battery is fully charged. Tripple clicking the tamper button includes (adds) and excludes (removes) the device. A click on the tamper witch will wake up the device.
  • Page 2 To open the POPP Mold Detector, press the lock with your finger and pull the housing cover upwards. Tamper button The tamper button is located on the side of the POPP Mold Detector. This button is also used for inclusion and exclusion. Functionality Once the device is powered up it will start monitoring the air parameters and warn of mold using the local red and green LED.
  • Page 3 store commands that can not be received during deep sleep state. Without such a controller, communication may become impossible and/or the battery life time is significantly decreased. This device will wakeup regularly and announce the wakeup state by sending out a so called Wakeup Notification. The controller can then empty the mailbox.
  • Page 4 1 - 65535 Seconds disabled Parameter 5: Temperature Upper Watermark value This parameter defines a temperature. If the measured temperature surpasses this watermark a BASIC command is sent into Association Group 2 Size: 2 Byte, Default Value: 0 Setting Description 1 - 1000 1/10 degree disabled...
  • Page 5 Weight 11.73 gr Hardware Platform ZM5101 4251295701202 IP Class IP 20 Voltage Battery Type 1 * 1/2 AA Device Type Notification Sensor Generic Device Class Notification Sensor Specific Device Class Routing Notification Sensor Firmware Version 01.00 Z-Wave Version 06.02 Z-Wave Product Id 0x0154.0x0004.0x0014 Supported Command Classes Basic...
  • Page 6 Wakeup Notification — is a special wireless message issued by a Z-Wave device to announces that is able to communicate. Node Information Frame — is a special wireless message issued by a Z-Wave device to announce its capabilities and functions. (c) 2019 Z-Wave Europe GmbH, Antonstr.