stations.
2.
Check the registration, and adjust using the following SP modes if necessary.
Side-to-side Registration
Leading Edge Registration (Simplex)
Trailing Edge Blank Margin
Sub Scan Magnification
Make a temporary test chart as shown above using A3/DLT paper.
1.
Place the temporary test chart on the ADF and make a copy from one of the feed
stations.
2.
Check the magnification, and adjust using the following SP modes if necessary. The
specification is ±1%.
Sub scan magnification
3.10.4 TOUCH SCREEN CALIBRATION
After clearing the memory, or if the touch panel detection function is not working correctly,
follow this procedure to calibrate the touch screen.
Do not attempt to use items [2] to [9] on the Self-Diagnostic Menu. These items
are for design use only.
1.
Press
, input 1993 at the ten-key pad, and then press
Self-Diagnostics menu.
SM
Copy Adjustments: Printing/Scanning
SP mode
SP6-006-1
SP6-006-2
SP6-006-3
SP mode
SP6-006-5
5 times to open the
3-67
D017/D018/D019/D020