INSTALLATION INSTRUCTIONS FOR SV4.5HTSS, SV4.5-20SSWSK AND ALL DERIVATIONS
OF THE SF-HTSS; SFKIT12-SS, SFKIT18-SS, SFKIT24SS, SFKIT26SS AND SFKIT48-SS KITS
Small Square Termination Kits
Cat. No
Model
H5817
SV4.5-20SSWSK Small Square Termination, Horiz. 20" w/Sheild
94L10
SV4.5HTSS
Small Square Termination, Horiz. - Rigid
H8915
SV4.5TK90SS
Small Square Termination, Horiz. Kit w/90
GENERAL INFORMATION
f i r e - p a r t s . c o m
Information provided here is supplemental to instructions provided with
each fireplace and may, for the most part, be redundant to that information.
The intent of this document is to provide complete instructions pertaining
to the installation of the before-mentioned terminations, particularly any
instructions that are exclusive to the installations of these terminations.
The SV4.5HTSS, SV4.5-20SSWSK and all derivations of the SF-HTSS;
SFKIT12-SS, SFKIT18-SS, SFKIT24-SS, SFKIT36-SS, and SFKIT48-SS
are intended for use ONLY with Innovative Hearth Products (IHP) 33",
35" and select other Direct-Vent gas fireplaces listed as follows; DRC/
DRT-2033/2035, DRC/DRT-3033/3035, DRL3042, DRL6542, Aries 33/35,
AriesCD 33/35, MPD33/35, MPD3328/3530, Gemini33/35, Rhapsody42,
Sirius42, Envy35, Envy35CD, MHD35, MLDVTCD-35, SSDV-3328/3530,
SDV35N, LMDV3328, LMDV-3530, MPLDV-30 and MPLDV-35,
VeniceLightsTEN, VeniceLightsTEP, DRL4543TEN, DRL4543TEP series
gas fireplaces.
These terminations MAY NOT be used with DRC/DRT-2040/2045,
DRC/DRT-4040/4045, DRT40-ST/PF/CR/CL, DRC/DRT-3540/3545,
DRC/DRT-3040/3045, DRT35ST/PF, DRL3054, DRL6554, Aries40/45,
AriesCD40/45,Altair40/45, Envy40/45CD, Envy40CD/45CD,
Eros35ST/PF, Gemini40/45, Libra40-ST/PF/CR/CL, Scorpio-35/40/45,
ScorpioCD-35/40/45, MHD40, MPD Pro, MPD40/45, MPD4035/4540,
MPD35ST/PF, Rhapsody 54, Sirius54, Spectra, EDV, ELDV and EDVST/
PF/CR/CL series gas fireplaces.
The terminations covered by this document seamlessly integrate with all
the other components of the above mentioned fireplaces approved for
use with these terminations, and when installed in accordance with the
directions provided here and with each fireplace constitute a complete,
approved and listed installation.
C
US
Report No. F114-140
Description
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
P/N 750204M
REV. H 04/2018
Framing
Frame the fireplace in accordance with the instructions provided with the
fireplace and refer to Figures 1, 4 and 5 for any dimensions applicable
to the SV4.5HTSS, SF-HTSS terminations.
NOTE: Venting requirements for rear vent applications in corner installations -
the horizontal vent length "a" to "b," must not exceed 28" (711 mm)
Framing should be constructed of 2x4 or larger lumber.
*These dimensions occur when one 45 degree
elbow is connected directly to the appliance
collar and the unit moved 1/2" (13 mm)
into the room. This 1/2" movement
is required to achieve a minimum of
5" (127 mm) in the F dimension.
SV4.5HTSS Termination
*F = 5"
(127 mm)
*34-5/16
(872)
33-1/8
(841)
*48-1/2
(1232)
Back wall of chase/enclosure (including any finishing materials)
CORNER FRAMING WITH SQUARE HORIZONTAL
TERMINATIONS (SV4.5HTSS)
Figure 1
HEARTH PRODUCTS
KITS AND ACCESSORIES
SMALL SQUARE
HORIZONTAL TERMINATION
SV4.5HTS
Termination
7 (178)
b
8-3/16 (208)
*24-1/4
(616)
*17-3/16
a
(437)
Inches
(millimeters)
b
1