RISCO Group’s AGM, Universal Advanced GSM/GPRS Stand alone Module, is a cellular communication module enabling any existing security panel to communicate through the GSM cellular network. The AGM can be used as the main communication line or as a backup to PSTN line using telephone line simulation. 1.1 Main Features...
Telephone Connector - Set: To security panel or to premises telephone in absence of control panel. J15: Used to set Negative (-) or positive (+) remove of inputs 1 - 4 (see page 8). Negative Remove (Default) Positive Remove AGM - Installation and Programming Instructions...
Caution: Failing to properly earthen this unit can result in an electric shock. The AGM Module should be located in a safe and dry place, away from radio and electromagnetic transmitting devices.
Screws Front Cover Figure 3. AGM– Installation Remove the two screws securing the AGM front cover (2, Figure 3). Tilt and rotate the front cover downwards until it locks vertically to the casing (alternately lift up to remove the cover).
Insert external cables (GND, Power, and Phone lines) through the cable passage (6, Figure 3). Align the AGM with the mounting holes and fasten it firmly to the wall with all four supplied screws (1, Figure 3). Attach the AGM antenna.
(with a delay of 5 seconds between each cycle), indicating the RSSI level (0= No network connection, 5= Very High). If the signal level is not satisfactory or poor, consider installing the AGM in a better signal receiving location.
PSTN line. 6. Monitoring Station Reporting The AGM enables to report events to two different Monitoring Stations, using Contact ID or SIA formats via three different channels: Voice, SMS, or GPRS.
(activated or deactivated by a remote SMS user command). Input 3 can also be defined as type “Switch from PSTN to GSM”. When a phone line is connected to the AGM, the user has the ability to manually switch the outgoing line from PSTN to GSM (Latch operation).
Follow Me number. 10. SMS User Remote Control Functions The AGM enables the user to remotely control the AGM using SMS commands. For security reasons, a user code (4 digits. Default user code 1234) has to be used to perform the SMS user commands.
Notes: 1. When calling the AGM from a PSTN line or from a different provider, the Data channel (CSD) in the SIM card should be enabled. 2. When calling the AGM from a number of the same provider the data channel is automatically enabled (Data number not required).
Page 15
4. Receiving SMS Confirmation Message (see page 20) The SMS commands can have a confirmation reply SMS message. To achieve that add [!] (Exclamation Mark) after the installer code. The AGM will send "0" for each command that succeeded and "4" for each command that failed.
The table below provides the entire set of commands available. The procedure of programming the commands is identical and uses the same syntax as described in the previous section. The order of the commands is identical to the order in the AGM Configuration Software.
Page 17
Standard Parameters :Periodic Test PRDT: Periodic Test Time 24 hour format 1200 The time that the AGM will automatically call a Follow Me HH:MM number in order to check communication with the AGM or (Example: 16:00=1600) send a test report signal to the Monitoring Station.
Page 18
0.0.0.0 SMPO: MAIL SMTP Port Max. 5 digits SMPR: MAIL Prefix Max. 16 chars The AGM Email address name section. For example, in the GSM@riscogroup.com E-mail address, the prefix name is “GSM”. SMDO: MAIL Domain Max. 32 chars The AGM module Email address domain section.
Page 19
9: Low battery each Follow Me. For more information 3: Input 3 10: SIM card expired refer to page 12. 4: Input 4 11: Periodic test 5: Tamper 12: Provider message 6: PSTN loss AGM - Installation and Programming Instructions...
Page 21
AGM will return the current AGM software version ST: AGM Status SMS Structure: [Code][ST] User only Sending the ST command to the AGM Example: 1234ST will return the status of the AC power, Battery status, PSTN line status and GSM signal level.
185 x 275 x 65 mm (7.2” x 10.8” x 2.6”) Width x Height x Depth With antenna installed: 185 x 335 x 65 mm (7.2” x 13.2” x 2.6”) Weight (with battery) 2.1kg (4.6lbs) AGM - Installation and Programming Instructions...
PRMV) Go to step 5 else go to step 4 4.If the dialed number has no prefixes known to the AGM, the module will add a Prefix (Prefix to add – SMS command ) defined in the security panel (usually used for the PADD local area code of the PSTN).
Page 24
(1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. RISCO Group USA Inc, 2822 NW 79Ave.. Miami, Florida 33122-1033 Tel: 1-305-592-3820 11-800-344-2025, Fax: 1-305-592-3825, Email: sales@rlnogroupusa.com...
Page 25
If trouble is experienced with this equipment US:RISAL10BAGM, for repair or warranty information please contact RISCO Group USA Inc 2822 NW 79th Ave. Miami, Florida 33122 USA, phone number 305 592 3820, URL: sales@riscogroupusa.com. If the equipment is causing harm to the telephone network, the telephone company may request that you disconnect the equipment until the problem is resolved.
Page 26
Supplier Declaration Of Conformity (SdoC) March 30, 2008 RISCO Ltd., Located at 14 Hachoma street, Rishon Lezion 75655, Israel, Hereby declare that the Advanced GSM unit, brand name AGM p/n RP200GSXMUSA, bearing labeling identification number US:RISAL10BAGM complies with the Federal Communications commission's ("FCC") rules and regulations 47 CFR part 68, and the Administrative Council on Terminal Attachments ("ACTA") adopted...
Page 27
RISCO Group Limited Warranty RISCO Group and its subsidiaries and affiliates ("Seller") warrants its products to be free from defects in materials and workmanship under normal use for 24 months from the date of production. Because Seller does not install or connect the product and because the product may be used in conjunction with products not manufactured by the Seller, Seller cannot guarantee the performance of the security system which uses this product.
Page 28
Contacting RISCO Group RISCO Group is committed to customer service and product support. You can contact us through our website (www.riscogroup.com) or as detailed below: United Kingdom Tel: +44-161-655-5500 Tel: +1-631-719-4400 technical@riscogroup.co.uk support-usa@riscogroup.com Italy Brazil Tel: +39-02-66590054 Tel: +55-11-3661-8767 support@riscogroup.it support-br@riscogroup.com...
Need help?
Do you have a question about the AGM and is the answer not in the manual?
Questions and answers