Step 8 Input y and press Enter to confirm the upgrade.
Step 9 Power off and on the auxiliary server after the upgrade.
Step 10 Log in to the OS of the auxiliary server as an administrator and run the following command to
check whether the SSD controller firmware is upgraded:
hioadm updatefw -d pd0
Step 11 Power off the auxiliary server, remove the upgraded SSD from the auxiliary server, and
reinsert it to its original slot on the target server.
Step 12 Power on the target server, go to BIOS, and check whether the RAID group is normal. If the
RAID group is abnormal, contact Huawei engineers.
----End

5.2.4.3 No RAID Card (Direct-Connection Mode)

If SAS SSDs directly connect to a server instead of through a RAID card, follow instructions
in
5.2.4.2.1 No RAID Group Created (JBOD Mode)

5.3 Querying Health Status

Operation Scenario
Check the SSD health status.
Procedure
Step 1 Log in to the OS as an administrator or a member in the administrator group.
Step 2 Run the following command to query the health status of the SSD controller (such as sda):
hioadm info -d sda
device status in the command output indicates the SSD controller health status.
l
l
root@ubuntu:~# hioadm info -d sda
formatted LBA size
formatted metadata size
maximum capacity
current capacity
volatile write cache
serial number
model number
firmware version
device status
----End

5.4 Information Collection

Issue 06 (2019-03-19)
healthy indicates that the SSD is healthy.
warning indicates that the SSD is faulty.
Copyright © Huawei Technologies Co., Ltd.
to upgrade SAS SSD firmware.
: 512 Byte
: 0 Byte
: NA
: 3200.6GB
: Disable
:
: HSSD-D5220AS0211
: 1907
: warning
5 Maintenance and Upgrade
51