While cooking, the temperature can be regulated using the control knob (No.2 in the
photo) from high flame to low flame in order to avoid over-cooking.
A safety thermocouple cuts the gas supply if the burner is extinguished. The low flame
of the appliance is pre-adjusted in the factory, it must not be changed. This extinction
can mainly occur when there is a lot of wind. In this particular case, just repeat the
switching-on procedures described above.
Your appliance is equipped with a tray (No. 5 in the photo) that is fully removable to
drain juice and fats. It must be cleared regularly. It is recommended to pour a little water
in the tray when you start cooking to facilitate maintenance and to avoid the solidifica-
tion and accumulation of fats at the bottom of the tray at the end of the meal.
Never use the appliance without the drip tray (No. 5 in the photo).

5. FUNCTIONING / HANDLING

a) Installation/Assembly:
- Carefully unpack the plancha from the cover and remove from its cardboard box.
- Place the plancha on a flat and heat-resistant surface.
- Never place the appliance near a wall or a partition made of combustible materials
even if it is properly insulated.
- A distance of minimum 10 cm with the partition or the wall is required.
- Remove the "Food enamel" label and the red label on the plate as well as the pro-
tective film around the appliance without forgetting to remove the film that protects
the juice collector tray (No. 5 in the photo). Use a solvent like acetone or other sol-
vents to remove these labels.
b) First use:
When you use this appliance for the first time, heat the plate outside for approx. 30 min
to remove any residual oil smoke from the manufacturing of the metal parts. This may
emit a slight smell for a few moments.
The appliance does not need to be kept switched on at full capacity: the tempera-
ture must be adapted to the products that are to be cooked to limit gas consump-
tion.
First cleaning
Clean the appliance before its first use. (Refer to. 6 Cleaning)
Gas connection
The appliances run on the following gases: Butane G30 and Propane G31. The appli-
ances are originally delivered with a Butane/Propane injector corresponding to the cate-
gory
I 3+.
The heat release rate of the appliance is
304145-165 en ma 2012-06
PL 400 G
PL 600 G
2.75 kW
5.50 kW
5/14