Download Print this page

Honeywell RTY Series Installation Instructions Manual page 5

Hall-effect position sensors

Advertisement

Hall-Effect Rotary
Position Sensors
Sensing range
Redundant version
Input voltage
Output
Input current
Operating temperature range
Connector
Life
EMI/EMC
Housing material
Dimensions
RPn Series
50° (±25°), 60° (±30°), 70° (±35°), 90° (±45°), 120° (±60°),
180° (±90°), 270° (±135°), 360° (±180°)
yes
5 Vdc, 8 to 30 Vdc, 10 Vdc to 30 Vdc
0.25 V to 4.75 V, 0.5 V to 4.5 V, 1 V to 9 V, 3 V to 5 V, 4.5 V to
0.5 V, 4.75 V to 0.25 V, 4 mA to 20 mA, 20 mA to 4 mA
20 mA max.
-40 °C to 125 °C [-40 °F to 257 °F]
AMP 1-1419168-1, AMP Superseal 282087-1,
Deutsch DT04-3P
30 M cycles
EMC: 200 V/m ISO 11452-3
PA66 plastic
63 mm L x 38,8 mm W x 56 mm H
[2.48 in L x 1.53 in W x 2.20 in H]
HRS100 Series
90° ±2°, 180° ±2°
no
5 Vdc ±10%
5% to 95% of applied Vdd, approx. (programmable)
(output ratiometric to supply)
5 mA typ.
-40 °C to 85 °C [-40 °F to 185 °F]
solder lug, flying wire leads
10 M cycles
EMI: 30 V/m, 10 kHz to 1000 MHz at 3 m
metal
32,27 mm [1.3 in] H x 27,79 mm [1.1 in] W

Advertisement

loading