Advertisement

Quick Links

Table of Contents

Rev 2.0 3/3/2017
K594.RF Product Guide
Table of Contents .............................................. Page 1
Overview and General Concept ......................... Page 2
Application ......................................................... Page 2
Features ............................................................ Page 3
Installation ......................................................... Page 3
Commissioning .................................................. Page 4
Using the E527/E527.4G ............................... Page 5
Using the E529 .............................................. Page 5
Binding the K594 ............................................... Page 6
Using the E527/E527.4G ............................... Page 6
Using the E529 .............................................. Page 7
Testing ............................................................... Page 8
PIR Specifications .............................................. Page 9
RF Specifications ............................................... Page 9
Technical Specifications .................................... Page 9
PIR Coverage .................................................... Page 11
Document Revision History................................ Page 11
K595.RF Product Guide
1

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell K594.RF

  • Page 1: Table Of Contents

    K595.RF Product Guide K594.RF Product Guide Table of Contents Table of Contents ..........Page 1 Overview and General Concept ......Page 2 Application ............Page 2 Features ............Page 3 Installation ............Page 3 Commissioning ..........Page 4 Using the E527/E527.4G ....... Page 5 Using the E529 ..........
  • Page 2: Overview And General Concept

    The K594.RF will process any actions instigated by those checks; after that (or if there is no action), it will enter a low-power state (Sleep Mode) to conserve battery power. The K594.RF can also act as a minibar server if the IO map is so programmed. Rev 2.0 3/3/2017...
  • Page 3: Features

    Placement for the K594.RF should provide maximum room coverage by the PIR motion detector while maintaining RF communication between the device and the e4 thermostat. Ideally, the K594.RF should be positioned on a wall in opposition to entrances and interior doors (8ft. high, 0° angle, 0°...
  • Page 4: Commissioning

    H2 Aux Input Header Commissioning To function as part of the in-room network, the K594.RF must be commissioned by accepting instruction as to room identification, RF channel, P5 address, P5 channel, and IOMap setting for the specific room (see IOMap Summary table below).
  • Page 5: Using The E527/E527.4G

    K595.RF Product Guide If Using the E528/E527.4G: 1. Enter Service Parameter Mode on the Thermostat: a) Press and hold °F/°C button b) Press and release the OFF/AUTO button c) Press and release the DISPLAY button d) Release the °F/°C button rId will be on the display 2.
  • Page 6: Binding The K594

    K595.RF Product Guide b) The next 2 digits of Room ID will be displayed with “MED” below it. Change to desired value with UP/DOWN arrow buttons and press DISPLAY button. c) The last 2 digits of Room ID will be displayed with “LO” below it. Change to desired value with UP/DOWN arrow buttons and press DISPLAY button to store Room ID.
  • Page 7: Using The E529

    K595.RF Product Guide If Using the E529: 1. In Service Parameter mode, go to the Io (I/O Map) parameter 2. Press OFF/AUTO button to view value. 3. Change the value to the desired I/O Map. If only using the K594 as a remote Motion Sensor and NOT using its external input to monitor a door switch or other contact, use I/O Map 0.
  • Page 8: Testing

    K595.RF Product Guide Name VIF 0x1E Control Reinforcement Frame Window Segment 1 0x1E 0x1E Window Segment 1 Inverted 0x1E 0x1E Window Segment 2 0x1E 0x1E Window Segment 2 Inverted 0x1E 0x1E Window Segment 3 0x1E 0x1E Window Segment 3 Inverted 0x1E 0x1E Window Segment 4...
  • Page 9: Pir Specifications

    K595.RF Product Guide PIR Specification Parameter K594.RF Lens Data 70ft No. of Fresnel Beams No. of Curtain Beams MAX. Coverage 12x12m (40x40ft.) 90 degrees Sensitivity 0.5m-12m (1.64-40ft) RF Specification Parameter K594.RF RF Data Rate 250kbps Antenna Type Indoor Range 70ft...
  • Page 10 K595.RF Product Guide Safety Regulatory FCC ID: GTC202150TXR or GTC202152TXR This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
  • Page 11: Pir Coverage

    Honeywell makes no representations or warranties with respect to this document. In no event shall Honeywell be liable for technical or editorial omissions or mistakes in this document, nor shall it be liable for any damages, direct or incidental, arising out of or related to the use of this document. No part of this document may be reproduced in any form or by any means without prior written permission from Honeywell.

Table of Contents