Pin assignment
EXTERNAL CONTROL connector (D-sub 15-
pin)
Pin No. Signal
1
FRAME GROUND 9
2
JT POWER +
3
UTILITY +
4
Reserved 1 +
5
Reserved 2 +
6
Reserved 3 +
7
Reserved 4 +
8
Reserved 5 +
Design and specifications are subject to change
without notice.
Pin No.
Signal
JT POWER –
10
UTILITY –
11
Reserved 1 –
12
Reserved 2 –
13
Reserved 3 –
14
Reserved 4 –
15
Reserved 5 –
JTC-C200 ICU controller
General
Power requirements
AC 100 – 240 V, 50/60 Hz, 0.13 A
Power consumption
13 W (max.)
481 × 132.4 × 228 mm (w/h/d)
Dimensions
(19 × 5
Mass
Approx. 5 kg (11 lb)
Operating conditions
Temperature: 0 °C to 45 °C (32 °F to
113 °F)
Humidity: 30% to 70% (no
condensation)
Input/output
Control
CONTROL 1, CONTROL 2:
D-sub 15-pin for RS-422 (2)
EXTERNAL CONTROL: D-sub
15-pin (1)
COM 1, COM 2: D-sub 9-pin (2)
Supplied accessories
AC power cord (3)
Operating Instructions (1)
Pin assignment
CONTROL 1 and CONTROL 2 connectors (D-sub
15-pin)
Pin No. Signal
1
GND
2
TXD +
3
RTS +
4
RXD +
5
CTS +
6
DSR +
7
DTR +
8
GND
× 9 inches)
1
/
4
Pin No.
Signal
9
TXD –
10
RTS –
11
RXD –
12
CTS –
13
DSR –
14
DTR –
15
Not used
Others
33