10. OPERATING INSTRUCTIONS
Operation of semi-automatic MIG welder 200M should take place in an atmosphere free of corrosive components and dusty. Do not place the device in
dusty, near the working grinders, etc. Dust and pollution control boards metallic filings, wires and connections inside the unit may cause an electrical
short, and consequently damage to the welding machine.
Avoid use in environments with high humidity, especially in situations of occurrence of dew on the metal parts.
In the case of dew on the metal parts, eg. The device after the cold into a warm room, wait until it is completely dry and warm the device to room
temperature. Starting in these conditions, cold welding can cause damage. It is recommended that in the event of welding operation outdoor place it
under a roof to protect against adverse weather conditions. MIG 200M should be operated under the following conditions:
-
changes in the effective value of the supply voltage is not greater than 10%
-
ambient temperature of from -10 ° C to + 40 ° C
-
Atmospheric pressure 860 to 1060 hPa
-
relative humidity of the atmosphere is not more than 80%
-
height above sea level to 1000m
You kaz wear parts:
You kaz wear parts:
lp
For steel wire
1
Roll feeder 30x10x12mm
2
Contact tip M6x25 TW-15 Al end of the current TW-15 M6x25 3
Contact tip M6x25 TW-15 Al end of the current TW-15 M6x25 3
4
5
The contribution of steel 3m
For a full list of consumables and spare parts is available on the website and in the company www.tecweld.pl TECWELD. There is a
possibility of direct purchase of these parts.

11. MAINTENANCE INSTRUCTIONS

As part of the everyday operation of the welder must be kept clean and check the status of the holder, cables and external connections.
Regularly replace consumables.
Periodically clean the inside of the device by purging with compressed air to remove dust and chips from metallic plates, and the control wires and
electrical connections. Not less than once every six months should be a general review of the status and electrical connections, in particular:
-
state of shock protection
-
the insulation
-
the state security
-
the operation of the cooling system
Damage resulting from the welding operation in unsuitable conditions and failure of recommendations for maintenance are not covered by
warranty repairs.
For aluminum wires
Roll feeder Al 30x10x12mm
The connector current TW-15
Gas nozzle TW-15
The contribution of Teflon 3m
10