Performance Data - Hev/H024 - Heat Controller HEV Series Engineering Design Manual

Residential packaged geothermal heat pump, 2 to 5 tons
Table of Contents

Advertisement

Heat Controller
Heat Controller, LLC
Performance Data
HEV/H 024 - Part Load
600 CFM Rated Air ow
WPD
EWT
GPM
°F
PSI
Operation Not
Recommended
20
4.5
3.1
2.3
0.6
30
3.4
1.5
4.5
2.4
2.3
0.4
40
3.4
1.1
4.5
1.9
2.3
0.2
50
3.4
0.8
4.5
1.6
2.3
0.1
60
3.4
0.7
4.5
1.4
2.3
0.1
70
3.4
0.7
4.5
1.2
2.3
0.2
80
3.4
0.6
4.5
1.2
2.3
0.2
90
3.4
0.7
4.5
1.2
2.3
0.2
100
3.4
0.7
4.5
1.1
2.3
0.2
110
3.4
0.6
4.5
1.1
2.3
0.0
120
3.4
0.5
4.5
1.0
†ARI/ASHRAE/ISO 13256-1 (WLHP applications) certi ed conditions are 86°F EWT, 80.6°F DB / 66.2°F WB
EAT in cooling and 68°F DB / 59°F WB EAT in heating.
Interpoaltion is permissable, extrapolation is not.
All entering air conditions are 80°F DB and 67°F WB in cooling and 70°F DB in heating
All performance data is based upon the lower voltage of dual voltage rated units
See performance correction tables for operating conditions other than those listed above.
Operation below 60°F EWT requires optional insulated water circuit.
Operation below 40°F EWT is based upon 15% antifreeze solution.
Performance capacities shown in thousands of Btuh
Cooling - EAT 80/67°F
FT
TC
SC
KW
Operation Not Recommended
7.2
1.5
22.9
15.4
0.7
3.4
23.3
15.5
0.6
5.6
23.5
15.5
0.6
0.8
22.3
15.1
0.7
2.5
22.8
15.4
0.7
4.5
23.0
15.4
0.7
0.5
21.5
14.7
0.8
2.0
22.1
15.0
0.8
3.7
22.4
15.2
0.7
0.3
20.7
14.3
0.9
1.6
21.3
14.6
0.9
3.2
21.6
14.8
0.8
0.3
19.6
13.8
1.1
1.5
20.4
14.1
1.0
2.9
20.7
14.3
0.9
0.4
18.5
13.3
1.3
1.5
19.3
13.6
1.1
2.7
19.7
13.8
1.1
0.5
17.2
12.8
1.5
1.5
18.1
13.1
1.3
2.7
18.5
13.3
1.3
0.5
15.7
12.3
1.7
1.5
16.7
12.6
1.5
2.7
17.1
12.8
1.5
0.4
14.1
11.8
1.9
1.4
15.1
12.1
1.8
2.6
15.6
12.3
1.7
0.1
12.3
11.1
2.2
1.1
13.4
11.5
2.0
2.3
13.9
11.7
2.0
HEV-HEH SEriES
HEV/H SERIES
HR
EER
HWG
HC
10.8
25.2
34.7
0.9
12.3
25.5
37.2
0.8
12.9
25.6
38.2
0.8
13.2
24.8
30.6
0.9
14.5
25.1
33.8
0.8
15.3
25.2
35.1
0.8
15.8
24.3
26.2
1.2
16.9
24.7
29.5
1.0
17.8
24.8
31.0
0.9
18.4
23.9
21.9
1.7
19.2
24.2
25.0
1.3
20.2
24.4
26.5
1.2
20.8
23.4
18.0
2.3
21.3
23.7
20.7
1.8
22.4
23.9
22.1
1.6
22.9
22.8
14.6
3.2
23.2
23.2
16.9
2.6
24.0
23.4
18.1
2.3
24.4
22.2
11.7
4.2
24.5
22.6
13.6
3.5
25.0
22.8
14.6
3.2
25.1
21.5
9.3
5.4
21.9
10.8
4.6
22.1
11.7
4.2
20.7
7.3
6.8
21.2
8.5
5.9
21.4
9.2
5.5
19.8
5.5
8.3
20.4
6.6
7.4
20.6
7.1
6.9
9
9
Engineering Design Guide
Heating - EAT 70°F
KW
HE
LAT
COP HWG
Operation Not Recommended
1.1
7.0
84.6
2.8
1.1
8.4
86.9
3.2
1.1
9.0
87.8
3.3
1.1
9.3
88.3
3.4
1.2
10.6
90.4
3.7
1.2
11.3
91.6
3.8
1.2
11.7
92.3
3.9
1.2
12.8
94.0
4.2
1.2
13.7
95.5
4.4
1.2
14.2
96.3
4.5
1.2
15.0
97.5
4.6
1.2
16.0
99.2
4.8
1.2
16.6
100.0
4.9
1.2
17.1
100.8
5.0
1.3
18.1
102.4
5.2
1.3
18.5
103.2
5.3
1.3
18.8
103.7
5.3
1.3
19.6
105.0
5.4
1.3
20.0
105.6
5.5
1.3
20.1
105.7
5.5
1.3
20.5
106.5
5.5
1.3
20.5
106.7
5.5
Operation Not Recommended
Design Guide
1.9
1.9
1.9
2.0
2.0
2.1
2.1
2.1
2.2
2.2
2.3
2.4
2.5
2.5
2.6
2.7
2.8
2.9
3.0
3.1
3.3
3.4