Page 1
Engineering Operation & VELOCITY PLASTIC PUMP Maintenance P U M P D E S I G N A T I O N S Y S T E M LEGEND V2550 / XXX X X / XXX / XX / XXX/ XXXX O-RINGS SPECIALTY...
Page 2
C A U T I O N S & W A R N I N G S PUMP TEMPERATURE LIMITS: PVDF and Polypropylene 4°C – 79°C (40°F - 175°F) CAUTION: Maximum temperature limits are based upon mechanical stress only. Certain chemicals will signifi cantly reduce maximum safe operating temperatures.
Page 3
D I M E N S I O N A L D R A W I N G V2550 PL ASTIC DIMENSIONS METRIC STANDARD ITEM (mm) (inch) LW0351 REV. D WIL-41000-E-06...
D I M E N S I O N A L D R A W I N G V2550 PL ASTIC - HORIZONTAL DIMENSIONS METRIC STANDARD ITEM (mm) (inch) LW0352 REV. C WIL-41000-E-06...
Page 5
D I M E N S I O N A L D R A W I N G A 2550V PL ASTIC DIMENSIONS ITEM METRIC STANDARD ITEM METRIC STANDARD (mm) (inch) (mm) (inch) LW0353 REV. D WIL-41000-E-06...
Page 6
V 2 5 5 0 P E R F O R M A N C E C U R V E Ship Weight ......2 kg (4 lb) Displacement stroke Air Inlet ......6 mm (1/4”) calculated at 4.8 bar (70 psig) air inlet Inlet ........
Page 7
V 2 5 5 0 D R Y S U C T I O N - L I F T C U R V E Suction-lift curves created Suction lift can be affected by using pumps operating at 305 m the number of intake/discharge (1000’) above sea level.
Page 8
A 2 5 5 0 V P E R F O R M A N C E C U R V E 1[2] 2[3] 3[5] 4[7] 5[8] .30+ .25 [11] [15] Ship Weight ......2 kg (4 lb) Displacement stroke Air Inlet ......6 mm (1/4”) calculated at 4.8 bar (70 psig) air inlet Inlet ........
Page 9
A 2 5 5 0 V 7 0 / 3 0 O P E R A T I N G C O N D I T I O N This curve demonstrates the fl ow created when the stroke rate is varied under static air and fl...
Page 10
S U G G E S T E D I N S T A L L A T I O N PUMP SELECTION: Ensure that the pump materials of construction are compatible with the pumping media and the immediate surroundings the pump will be subjected to. Refer to the Wilden Chemical Resistance Guide.
Page 11
B A S I C T R O U B L E S H O O T I N G Pump will not run or runs slowly: 1. Ensure the air inlet pressure is 0.3 bar (5 psig) above the start-up pressure of the pump.
Page 12
D I S A S S E M B L Y / R E A S S E M B L Y Tools Required: CAUTION: Before any maintenance or repair is attempted, the • 5/16” Socket Wrench compressed air line to the pump should be disconnected and all air •...
P A R T S L I S T I N G V2550 A2550V V2550 A2550V Item Description Qty. /PPPPE/…/P/N /PPPPA/…/P/N /KKPPE/…/P/N /KKPPA/…/P/N AIR DISTRIBUTION COMPONENTS Air Valve Assembly 00-2044-99 00-2044-99 Air Valve Assembly, Solenoid 00-2014-99 00-2014-99 Gasket, Solenoid Valve 00-2640-56 00-2640-56 O-Ring, Shaft (-110, Ø.362"...
Page 15
E L A S T O M E R O P T I O N S DIAPHRAGM POLY BALL PVDF BALL BACK-UP CHECK CHECK MANIFOLD DIAPHRAGMS SEAL CARTRIDGE CARTRIDGE O-RINGS MATERIAL PTFE 00-1044-55 00-9189-55 00-9188-55 Sanifl ex™ 00-1074-56 Wil-Flex™ 00-1044-58 00-9189-58 00-9188-58 38-1371-58...
Page 16
W A R R A N T Y Each and every product manufactured by Wilden Pump & Engineering, LLC is built to meet the highest standards of quality. Every pump is functionally tested to insure integrity of operation. Wilden Pump & Engineering, LLC warrants that pumps, accessories and parts manufactured or supplied by it to be free from defects in material and workmanship for a period of fi...