Clearing Clog - Bissell PowerForce 6579 SERIES User Manual

Powerforce bagless vacuum
Table of Contents

Advertisement

M
aintenance and care

Clearing clog

Low suction, poor pickup, or no suction may be
due to a clog in the vacuum cleaner. If you notice
a change in the sound of the vacuum motor or a
reduction in the spinning action in the dirt
container, check for clogs.
1.
Unplug cleaner from electrical outlet.
2.
Empty dirt container.
3.
Check upper tank and louvers for build up or
clogs. Check to make sure louvers are installed
correctly. To unlock the louvers, grasp the rim
and turn toward the left. Pull straight down to
remove. If the louvers are missing or not locked
into place, check and clear the tube in the
center of the dirt container.
4.
Remove the Twist 'n Snap hose from the
vacuum by turning to the left. Check the
suction inlet, hose and hose wand for clogs.
Remove any clogs from the hose using a
long, narrow object.
5.
Check the foot hose for clogs. If needed,
remove the screw attaching the hose wand
base to the vacuum. Straighten the foot hose
and unclog with a long, narrow object.
6.
If the clog persists, follow the instructions for
checking the rotating floor brush on page 10
and inspect the air passageway for obstructions.
12
w w w . b i s s e l l . c o m
ug310-5825_6579_107.indd 12
ug310-5825_6579_107.indd 12
Louvers
Hose
Wand Base
Air Passageway
8 0 0 . 2 3 7 . 7 6 9 1
Suction
Inlet
1/18/07 1:29:37 PM
1/18/07 1:29:37 PM

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

6579-3

Table of Contents