9. After finish the welding job, press the temperature setting knob-
the hot air blower in a cold blowing condition for 5 mins in order to cool the
nozzle. Then to power off the welder.
temperature data, before you power off the welder, you can press down
both
you restart the welder.
x.
Fault diagnosis and solved ways
The fault
performance
Welder cannot walk
when hot air nozzle
at the right place
The position between
hot air nozzle and
drive roller is not
right
xi.
Routine maintenance
Use steel brush to clean the hot air nozzle
Clean the air inlet at the back of the hot air blower
to cold the hot air nozzle in 5 mins. And press both
Caused reasons
Micro switch is
not in right
place
If you want to keep the welding
Solved ways
Move the hot air nozzle to the left and
put it in place, then loosen adjusting
screw (17);
Move baffle of micro switch (18 ) , to
place micro switch ( 16 ) in the right
position
Adjust the fixed set ( left) of hot air
blower(14) and fixed set ( right ) of hot air
blower( by adjusting the screw under the
fixed set of hot air blower)