Carrier AquaEdge 19DV Series Start-Up, Operation And Maintenance Instructions Manual page 30

Two-stage back-to-back centrifugal liquid chillers with pic6 controls and hfo r-1233zd(e) 50/60 hz
Table of Contents

Advertisement

]
Main Menu
DESCRIPTION
Auto Restart Option
Common Sensor Option
EC Valve Option
No=0, Cont.=1,ON/OFF=2, mA=3
EC Selection
Disable=0, Surge=1, Low Load=2,
Comb=3
ECV Open IGV1 Position
ECV Close IGV1 Position
ECV Off DT for Low Load
ECV On DT for Low Load
ECV Low Load DB
Head Pres Valve Option
Head Pres Delta P 0%
Head Pres Delta P 100%
Head Pressure Min Output
Tower Fan High Setpoint
Refrig Leakage Option
Refrig Leakage Alarm mA
Oil EXV Option
Oil Temp High Threshold
Oil Temp Low Threshold
Gas Torque Factor
Guide Vane/SRD Factor
Power Recovery Timeout
Condenser Flush Alert
Customer Alert Option
Ice Build Option
Ice Build Recycle
Ice Build Termin Source
Temp=0,Contact=1,Both=2
Water Pressure Option
No=0, Pres.=1, Pres.D=2
Water Flow Measurement
No=0, Flow Meter=1,Water Pres. D=2
Water Flow Determination
Sat Temp=0,Flow Switch=1
Water Flow at 4mA
Water Flow at 20mA
Evap Flow Rate Baseline
Evap Pres Drop Baseline
Cond Flow Rate Baseline
Cond Pres Drop Baseline
Water Pres Drop @20mA
Max Oil Pressure Diff
Oil Pump VFD Max Step
Vapor Source SV Delay
Vapor Source SV Option
Liquid Bypass Selection
Purge On Idle Option
Evap Liquid Temp Opt
Evap App Calc Selection
Sat Temp=0, Ref Temp=1
Table 15 — Option Configuration

Configuration Menu
RANGE
Dsable/Enable
Dsable/Enable
0 to 3
0 to 3
0.5 to 10.0
1.5 to 20.0
0.5 to 10
0.5 to 10
0.5 to 2.0
Dsable/Enable
20 to 85
20 to 85
0 to 100
55 to 105
Dsable/Enable
4 to 20
Dsable/Enable
100 to 140
90 to 130
0.25 to 3.00
0.70 to 1.20
0 to 60
Dsable/Enable
Dsable/Enable
Dsable/Enable
Dsable/Enable
0 to 2
0 to 2
0 to 2
0 to 1
0 to 200
0 to 200
0 to 150
0 to 20
0 to 150
0 to 20
10 to 40
35 to 60
0 to 10
0 to 10
Dsable/Engale
Dsable/Enable
Dsable/Enable
Dsable/Enable
0 to 1

Option Configuration [CONF_OPT
UNITS
DEFAULT
%
%
^F
^F
^F
PSI
PSI
%
°F
mA
°F
°F
min
GPS
GPS
GPS
PSI
GPS
PSI
PSI
PSI
%
min
30
VALUE
Dsable
Jobsite specific
Dsable
Jobsite specific
0
2 (if selected)
0
Jobsite specific
5
5 (adjust as required)
10
10 (adjust as required)
4
4 (adjust as required)
2
2 (adjust as required)
1
1 (adjust as required)
Dsable
Jobsite specific
25
25 (adjust as required)
50
50 (adjust as required)
0
0 (adjust as required)
75
75 (adjust as required)
Dsable
Jobsite specific
20
20 (adjust as required)
Dsable
Dsable
122
n/a
113
n/a
1
1
0.95
0.95
15
15
Dsable
Dsable
Dsable
Jobsite specific
Dsable
Jobsite specific
Dsable
Jobsite specific
0
Jobsite specific
0
Jobsite specific
0
Jobsite specific
0
Jobsite specific
0
(adjust as required)
0
(adjust as required)
0
(adjust as required)
0
(adjust as required)
0
(adjust as required)
0
(adjust as required)
10
(adjust as required)
50
n/a
7
n/a
5
n.a
Dsable
n.a
Dsable
Per selection
Dsable
(adjust as required for force)
Enable
n/a
1
1