GNC P530 Operation And Parts Manual

GNC P530 Operation And Parts Manual

Hide thumbs Also See for P530:

Advertisement

Operations and Parts Manual
Specifications
Maximum Flow............................................................ 10 GPM
Maximum Pressure..................................................... 600 PSI
Maximum RPM.......................................................... 800 RPM
Maximum Temperature................................................. 140 F
Inlet Port..............................................................................1"
Outlet Port (Pressure)........................................................3/8"
Outlet Port (Regulator Return Line)..................................3/4"
Shaft Size.........................................................................24mm
Dimensions:
Tall/Compact Mounted:..................19"H x 12"W x 15"L
Low Mounted................................. 14"H x 12"W x 15"L
Weight........................................................................... 35 Lbs.
GNC Industries, Inc., 1401 Pace Rd., Pocahontas, AR 72455
Fax: 870-248-9905 Email: sales@gnci.org
P530 PUMP
(P10W)
1-870-248-9901
Website: www.gncindustries.com
1

Advertisement

Table of Contents
loading

Summary of Contents for GNC P530

  • Page 1 Outlet Port (Regulator Return Line)…………………….……...3/4” Shaft Size……………………………………………….………………24mm Dimensions: Tall/Compact Mounted:………..…….19”H x 12”W x 15”L Low Mounted…………………………... 14”H x 12”W x 15”L Weight………………………………………….…………………….. 35 Lbs. GNC Industries, Inc., 1401 Pace Rd., Pocahontas, AR 72455 1-870-248-9901 Fax: 870-248-9905 Email: sales@gnci.org Website: www.gncindustries.com...
  • Page 2: Warranty

    No allowance will be made for consequential damage, labor or penses incurred as the results of a proven defect. In no event will GNC Industries, Inc. be liable for any loss of profits or other conse- quential damages, even if GNC Industries, Inc. has been advised of the possibility of such damages.
  • Page 3: During Use

    Warning:  1. Never point the spray gun at people or animals. 2. The pump will produce high temperatures when operating. 3. Keep hands and clothing clear of the belts and pulleys when operating the pump. Before Use/Start Up:  1.
  • Page 4: Maintenance

    After Each Use:  1. Set the pressure regulator switch to “Pressure Release”, and run the pump with clean water to prolong the life of the pump. 2. Set the pressure regulating knob to “START” when the pump is not in use. Maintenance: ...
  • Page 9 U-Packing ▲■ ▲■ O-Ring ▲■ ▲■ Pump Kits P530 Regulator Assembly Ref # 200 43-530-200 43-530-325▲ Pump Packing Rebuild Kit Includes Ref # 45—49N Pump Cylinder Assembly Ref # 40, 45-49N & 60A 43-530-335 43-530-350 ● Pump Valve Kit Includes 6 of Ref # 54A...
  • Page 10 8. Suction line too small 16. Drive pulley spinning on pump or engine shaft. Replace drive key. REPAIR KITS P530 Regulator Assembly Ref # 200 43-530-200 Pump Packing Rebuild Kit Includes Ref # 45—49N 43-530-325▲ Pump Cylinder Assembly Ref # 40, 45-49N & 60A...
  • Page 11: Quick Reference

    Quick Reference Pressure Oil Fill Use: Regulator Non Detergent Oil Sight Gauge Knob (On Back Plate) 3/4” Return Pressure Release Secure Pulley Bolt to Key Way with Gauge Blue Lock Tight Output to 1” Suction Reel Initial Set-Up Check Pump and Engine Oil Levels ...

Table of Contents