Technical data

Note
Technical data apply for a rated input voltage, rated load and 25 °C ambient temperature if
nothing else is specified.
6.1

Input

Rated voltage U
in rated
Voltage range
Remark
Wide-range input
Connect/shutdown threshold, typical
Line supply buffering at I
Power-failure buffering
Rated line frequency
Line frequency range
Input current at the rated input voltage
of 120 V
Input current at rated input voltage
230 V
Inrush current limiting (25 °C), max.
I²t, at 120 V AC, max.
I²t, at 230 V AC, max.
Integrated input fuse
Protection in the line feeder cable
(IEC 898)
Power consumption (active power) at
full load
Overvoltage strength
SITOP PSU6200 1ph
Manual, 03.2019, A5E44623264-1-76
6EP3323-7SB00-0AX0 (12 V/7 A)
AC: 120 V - 230 V; DC: 120 V - 240 V
AC: 85 V - 264 V; DC: 99 V - 275 V
Derating at U
I
out rated
Yes
81 V AC / 49 V AC
, min
20 ms
out rated
at 120 V / 230 V
50 - 60 Hz
47 - 63 Hz
1.5 A AC / 0.9 A DC
0.9 A AC / 0.5 A DC
29 A
0.4 A
s
2
1.3 A
s
2
Fuse T 3.15 A
Recommended: Miniature circuit
breaker characteristic C, 6 A
100 W
300 V AC for 30 seconds
< 102 V AC: max. 80 %
in
6EP3324-7SB00-3AX0 (12 V/12 A)
AC: 120 V - 230 V; DC: 110 V - 240 V
AC: 85 V - 264 V; DC: 85 V - 275 V
-
83 V AC / 58 V AC
20 ms
1.3 A AC / 1.4 A DC
0.8 A AC / 0.7 A DC
6 A
1 A
s
2
0.5 A
s
2
Fuse T 6 A
Recommended: Circuit breaker, C
characteristic, 6 A
97 W
6