Functional Characteristics; Additional Options Via Remote / Front Control; Default Parameters; Ekip Power Controller - ABB SACE Emax 2 Series Instructions For Use Manual

Low voltage air circuit-breakers
Table of Contents

Advertisement

Functional characteristics The Ekip Touch trip unit, in addition to the protection and measurement menus, also allows various operating
Additional options via remote /
front control

18 - Default parameters

19 - Ekip Power Controller

26 | © 2018 ABB | 1SDH001316R0002 - ECN000086018 - Rev. C
and configuration parameters to be set on the screen:
• Line frequency, to set the installation frequency.
• Remote / Local Mode, to set the operating mode and enable editing of parameters and sending remote
commands.
• Local Bus, to enable communication with the terminal modules and communication on the Local Bus.
• Harmonics, to enable the calculation of current and voltage harmonics.
• Power controller, to enable the function Ekip Power Controller.
• Programmable functions, to combine the modification of parameters and configurations to the
programmable inputs of Ekip Signalling modules.
• System, to modify system data such as date, time, language and password.
• Maintenance, to optimize maintenance operations on the circuit-breaker.
Ekip T&P, Ekip Programming and Ekip Bluetooth allow the protection trip unit to be connected to Ekip
Connect software and to access parameters and commands that cannot be accessed directly from the front
interface:
• Parameters and commands that identify the CB (CB label, User data, Additional pages, Installation
data, Alive Led, Wink command).
• Additional measurements (Load Profile Timers).
• Additional commands (management of Open CB / Close CB commands, additional zone selectivity
functions, Glitch commands),
• Additional parameters (programmable states, protection locks, filters, management of communication
data, options double set A-B, Wizard).
Parameters, measurements and commands are also available when communication is activated via Ekip Com
modules.
Further details about the single options are available in the Design Engineering manual 1SDH001330R0002.
Details related to this chapter are available in the manual
available on the website ABB library.
Details related to this chapter are available in the manual
available on the website ABB library.
1SDH001330R0002
(Emax 2 engineering manual)
1SDH001330R0002
(Emax 2 engineering manual)
Ekip Touch protection trip unit | 18 - Default parameters
ABB | SACE Emax 2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents