(for example on the flange). Should additional information be required, please do not hesitate to contact POMPETRAVAINI or the closest representative. Should there be any difficulties in repairing the pump, it is recommended to send the pump for repair to POMPETRAVAINI or the local authorised representative.
1 - STEPS TO BE FOLLOWED PRIOR TO PUMP DISASSEMBLY Should pump repairs be required, it is recommended to acquire full familiarity of the procedures to be followed by studying these instructions and the “Operating Manual for Centrifugal Pumps”. FOLLOW THE SAFETY INSTRUCTIONS LISTED UNDER CHAPTER 2 OF THE AFORE MENTIONED OPERATING MANUAL.
(for the main dimensions see tab. 2 - 3 - 4 - 6 of chapter 10). When new parts are required always insist on original parts from POMPETRAVAINI. In case of doubts or should there be any questions regarding the above, do not hesitate to contact POMPETRAVAINI or the nearest authorised representative.
For more information and the assembly dimensions pls contact POMPETRAVAINI or its closest representative. Clean the stationary seal element removing encrustation, oxidation and deposit of the flushing liquid. Lubricate the seat and the elastomers of the stationary seat with oil that is compatible with the seal elastomers.
install the seal cover VDMA 471 on the shaft, the cooling cover VDMA 165 with the studs in place, then all the required gaskets and the pre-assembled shaft sleeve. Prior to finalise the mechanical seal assembly, already fitted on the shaft sleeve, it is recommended to clean both seal faces with a clean and soft tissue.
Specify also the VDMA number of the required part, as seen on the pump sectional drawing and parts list for proper identification of spare parts. We recommend the use of original spares: in case this is not respected, POMPETRAVAINI declines any responsability for eventual damages caused by not original spare parts.
Page 8
8 - SECTIONAL DRAWINGS AND TYPICAL OPTIONS 903.3 400.1 904.1 502.1 421.5 940.2 360.2 400.2 903.1 400.3 902.2 433.2 902.1 903.4 901.1 Fig. 2 - Pump series TCH gr. 1 & 2 design /1-C = Single mechanical seal NOTE: VDMA 925 applies only to stainless steel design 904.1 360.2 400.2...
Page 9
903.3 400.1 902.1 360.1 421.4 932.3 502.1 360.2 421.5 940.2 400.2 400.3 903.1 433.2 902.2 400.4 903.4 Fig. 4 - Pump series TCH gr. 3 design /1-C = Single mechanical seal 904.1 902.2 135.2 900.1 900.2 400.1 Fig. 5 - Pump series TCA - MCU-CHA Fig.
Page 10
903.3 902.2 412.3 412.2 902.1 400.5 400.2 502.1 360.2 940.2 400.3 421.5 901.1 903.1 400.1 903.4 Fig. 7 - Pump series MCU-CH gr. 3 design /R = Single mechanical seal NOTE: VDMA 925 applies only to stainless steel design 412.3 412.2 400.5 433.2...
Page 11
412.3 412.2 412.3 412.2 932.1 433.2 433.1 400.5 433.2 400.5 433.2 Fig. 10 - Option for design /1-RR Fig. 11 - Option for design /1-R2 = Cooled and double mechanical seal = Cooled and double mechanical back to back seal in series 903.3 400.1 903.2...
Page 12
433.2 433.1 400.9 902.3 Fig. 13 - Option for design /RR Fig. 14 - Option for design /B = Double mechanical seal back to back = Packed stuffing box 903.3 400.1 932.1 412.1 320.2 505.2 421.5 502.1 940.2 360.2 400.2 901.1 903.1 900.1...
10 - ENGINEERING TABLES Fig. 17 - Torque values for various bolt sizes Torque values (Nm) Bolt diameter (mm) at threaded area DIAMETRO DEI FILETTI DELLE VITI TCH - TCT - TCA Tab. 2 - Pumps series * MECHANICAL RADIAL SEAL RINGS PACKING RINGS BEARINGS TYPE SEAL...
Page 15
TCH/1X gr. 3 Tab. 3 - Pumps series * MECHANICAL PUMP RADIAL SEAL RINGS PACKING RINGS BEARINGS TYPE SEAL TYPE TYPE for SHAFT Dim. x N° rings (mm) Ø (mm) 65-315 Seal side Seal side 80-315 N°1 N°1 100-250 NU301 AS55708 = 55 100-315...
Page 16
MCU-CH group 3 NS and 4 NS Tab. 5 - Pumps series * MECHANICAL PUMP RADIAL SEAL RINGS PACKING RINGS BEARINGS TYPE SEAL MODEL TYPE for SHAFT Dim. x N° rings (mm) Ø (mm) 100-315 Seal side Seal side On sleeve = 55 100-400 N°1 NU309 (45x100x25)
Page 19
NOTES PUMP model Serial Number Computer Number Year of manuf....................................LIQUID handled Capacity Suction Pressure Discharge Press. Temperature ..................m ......m ......m ....°C Lethal Toxic Noxious Corrosive Irritant Malodorous ....Clean Dirty With suspended parts Spec. Gravity... Viscosity....
Page 20
SERVICE LIQUID RECIRCULATION NA5.SM.TCH0.GB00 / PRINTED IN ITALY Smontaggio TC… - MCU-… Inglese POMPETRAVAINI’S continuing research results in product improvement, therefore any specifications may be subject to change without notice. S.p.A. 20022 CASTANO PRIMO (Milano) ITALY Via per Turbigo, 44 – Zona Industriale Tel.