Details of Parameters
Parameters for Function Selection
PrNo. Parameter
00
Axis address
・With the mains power ON, the current
value of RSW ID (0 to F) on the LED
touch panel is downloaded to the driver
as the value of this parameter.
・The value of this parameter cannot be
modified by other means than the rotary
switch (RSW) ID.
01
Initial LED
status
Reading (pulse count) of the
position error counter
Unit: pulse
+:generates
   CCW-torque
−:generates
   CW-torque
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Value
0 〜
If multiple axes are used, it is necessary for the river to identify
15
the current axis that is accessed by the host (e.g. PC). You
【1】
can identify axis address by number with this parameter.
0 〜 2
You can select the type of information to be displayed initially
【1】
on the 7-segment LED at power on.
Power ON
Pr01 value
0
Motor speed
Unit: r/min.
+:runs in CCW
−: runs in CW
− App. 30 −
Default setting is shown by [  ]
Function
ID
MODE
SET
IM
SP
1
Motor torque
Unit: %
+:generates  
−:generates   
G
Flashes  (about  two
seconds) during the
initializing process
2
CCW-torque
CW-torque

Hide quick links: