Shown in temperature scale °C or °F. Switch by pressing
E14 Suction press
Function:
Shows current suction pressure for compressor.
Value:
Shown in units of Bar or Psi relative to atmosphere pressure. Switch by pressing
sure is shown in BarE, at °F in Psi).
E15 Discharge press
Function:
Shows current discharge pressure for compressor.
Value:
Shown in units of Bar or Psi relative to atmosphere pressure. Switch by pressing
sure is shown in BarE, at °F in Psi).

11.12 Operation parameter settings

By pressing
the Operation menu is selected. The
Use the arrow keys
The Operation menu includes the following parameters:
O01 Setpoint
Function:
The function is used for changing the setpoint.
Change the value to the desired value and press the Enter key
Value:
-
O03 Control mode
Function:
Setting the control modes: STANDARD or STARCON mode.
If STANDARD mode is selected:
In Chill mode, the evaporator fans run at high speed unless:
a. The setpoint Tset ≥ -4.9°C (23.2°F) and
b. The air exchange is closed and
c. Dehumidification is off and
d. CA/AV+ is inactive In Frozen mode the evaporator fans run at low speed.
If STARCON mode is selected:
See "11.23.1 StarConomy" p. 54.
Value:
Function set to STANDARD, STARCON. Default is customer dependent.
O04 Reference relative humidity setting
Function:
Setting of reference relative humidity. Note that container relative humidity is only reducible.
Value:
Shown as 'Off' or a percent value. Value can be set to Off or values from 50% to 95% in 1%
increments. Default = off.
O05 Datalog interval setting
Function:
Setting of interval between loggings in the datalog.
Setting the datalog interval to 60 min. (default value) allows logging of data for over a year.
Value:
Interval set to 15, 30, 60, 120 or 240 min. Default 60 min.
and
to navigate and the Enter key
.
icon is displayed.
to select.
for 3 seconds to acknowledge.