14.1 Alarm list

The following list includes a view of all alarms as listed on the display and a longer text. This list is
subject to constant updates.
Be sure to visit alarm.starcool.com for latest update.
Id
Display text
1. Temperature sensor alarms
102
Tret invalid
105
Tsup 1 invalid
108
Tsup 2 invalid
111
Tusda 1 out of range
114
Tusda 2 out of range
117
Tusda 3 out of range
120
Tcargo out of range
123
Tevap invalid
126
Tsuc invalid
129
Tamb invalid
132
Tpump invalid
146
PTI recommended
148
Tsup error
2. Pressure transmitter alarms
203
Pdis invalid
207
Psuc invalid
214
Pmem invalid
250
Config Psuc/Pdis
3. Other sensors
302
RH invalid
303
AirEx invalid
306
HPS switch - K1
310
CO
sensor invalid
2
313
O
sensor invalid
2
314
Replace CO
sensor
2
315
Replace O
sensor
2
4. Power alarms
400
Mevap 1 over heat
401
Mevap 2 over heat
402
Mcond over heat
403
Mpump over heat
415
Over voltage
418
Under voltage
421
Over current
423
No phase direction
424
Power frequency
425
Frequency too high
430
Cpr connection
5. FC alarms
501
FC local control
508
Compr connection
509
FC 24 V fault
510
Compr connection
511
Compr over current
513
Compr overload
514
Invalid power sup
Operating and service manual
Description
Return air temperature sensor invalid
Supply air temperature sensor 1 invalid
Supply air temperature sensor 2 invalid
USDA 1 temperature sensor invalid
USDA 2 temperature sensor invalid
USDA 2 temperature sensor invalid
Cargo temperature sensor invalid
Evaporator temperature sensor invalid
Suction temperature sensor invalid
Ambient temperature sensor invalid
Vacuum pump temperature sensor invalid
Reliability calculation signals something is wrong
Supply air temperature error
Compressor discharge pressure transmitter invalid
Compressor suction pressure transmitter invalid
Also activated by alarm 977, 978 (voltage reference fault)
Wrong suction pressure transmitter
Relative humidity sensor invalid
Air exchange sensor short circuit
High pressure switch is active
CO
sensor communication missing
2
O
sensor communication missing
2
Replace CO
sensor
2
Replace O
sensor
2
Evaporator motor 1 overheat
Evaporator motor 2 overheat
Condenser motor overheat
Vacuum pump motor overheat
U1-2 and U1-3 and U2-3 overvoltage
U1-2 and U1-3 and U2-3 undervoltage
I1-2 and I1-3 and I2-3 overcurrent
Phase direction not detectable
Phase frequency error
Power frequency too high
Power cable from FC to compressor faulty
FC setting in local mode
FC short circuit
FC internal 24 V supply fault
FC earth fault
Compressor over current
Compressor overload
FC undervoltage fault
Alarm type
Alarm
Alarm
Alarm
Log
Log
Log
Log
Warning
Alarm
Alarm
Alarm
Log
Alarm
Alarm
Alarm
Alarm
Alarm
Alarm
Alarm
Fatal alarm
Alarm
Alarm
Warning
Warning
Fatal alarm
Fatal alarm
Fatal alarm
Alarm
Fatal alarm
Fatal alarm
Fatal alarm
Fatal alarm
Log
Fatal alarm
Alarm
Alarm
Alarm
Alarm
Alarm
Alarm
Alarm
Alarm