Annual Inspection; Checking The Fluid Level - MAHA TWIN F IV 3.0 Series Original Operating Instructions

Table of Contents

Advertisement

Pos: 93 / Tec hnische Dokume ntation/Papierkorb/Übersc hriften/ Überschrif t 1.1: Jähr lic he Überprüf ung @ 6\mod_ 1174482245718_ 75.docx @ 76817 @ 2 @ 1
6.3

Annual Inspection

Pos: 94 / Tec hnische Dokume ntation/Alle Geräte/Inhalte/Inf o!/Inhalt: I nfo - J ährlic he Überprüfung_12pt @ 25\mod_ 1324460481075_ 75.docx @ 1139412 @ @ 1
• The maintenance interval prescribed by the manufacturer is 12 (twelve) months.
This maintenance interval refers to normal workshop usage. If the equipment is
used more frequently or under severe operating conditions (e.g. outdoors), the
interval must be reduced accordingly.
• Maintenance work shall be done only by authorized and trained service
technicians provided by the manufacturer, licensed dealers or service partners.
• In case of non-compliance the manufacturer's warranty becomes void.
Pos: 95 / Tec hnische Dokume ntation/Hebetechnik/00
HBZ Alle/Inhalte/Inf o!/Inha lt: Inf o - DG UV Re ge l 100- 500 / DG UV Grundsatz 308-003_12pt @ 47\mod_ 1483611185270_ 75.docx @ 2804763 @ @ 1
Pos: 96 / Tec hnische Dokume ntation/Alle Geräte/Übersc hriften/ Überschrifte n 1.1/Ö/Übersc hrif t 1.1: Ö lstand prüf en @ 20\mod_1268827315211_ 75.docx @ 827233 @ 2 @ 1
6.4

Checking the Fluid Level

Pos: 97 / Tec hnische Dokume ntation/Hebetechnik/00
HBZ Alle/Inhalte/Inha lt: Öls ta nd prüfe n HBZ ohne RFH ( Text) _12pt @ 38\mod_ 1407153967713_ 75.docx @ 2062253 @ @ 1
1 Lower lift into bottom position.
2 Check the fluid level (see label on power unit).
3 Open the filler neck and top up the reservoir. For specification and fluid quantity
see label on power unit.
4 Also perform a visual check of all hydraulic pipes and hoses.
Pos: 98 / Tec hnische Dokume ntation/Hebetechnik/00
HBZ Alle/Inhalte/Inf o!/Inha lt: Inf o - Ta usc h von Ö l und Druc kschlä uc hen_12pt @ 26\mod_ 1325753763930_ 75.docx @ 1147073 @ @ 1
• Replace the hydraulic fluid periodically, depending on aging, soiling and water
absorption.
• When topping up, use fluid with the same specification only.
• If the lift is operated permanently at an ambient temperature of < 15 °C (59 °F),
use hydraulic fluid with a lower viscosity.
• The pressure hoses should be replaced as required, but after six years at the
latest.
Pos: 99 /----- Forma t-----/MAN UELLER UM BRUCH Se itenumbruch @ 0\m od_1134403577687_ 0.docx @ 1277 @ @ 1
25
BA083101-en

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents