Technical specifications
7.7 Switching properties
Switching properties
IEEE 802.1Q tags (VLAN ID, priority)
transparent forwarding
Maximum frame size
Forwarding of PRP frames (Parallel Redundancy Protocol)
Note
The number of SCALANCE XB-100 modules connected in a line influences the frame delay.
When a frame passes through the IE switch, this is delayed by the store-and-forward function
of the SCALANCE XB-100 by 10-130 microseconds (at 100 Mbps).
Mechanical stability (in operation)
Device
SCALANCE XB108-2(SC)
SCALANCE XB108-2(ST)
SCALANCE XB112
SCALANCE XB116
SCALANCE XB124
40
IEC 60068-2-27 shock
15 g, 11 ms duration
6 shocks per axis
●
●
●
●
●
Operating Instructions, 02/2019, C79000-G8976-C473-03
Yes
1536 bytes
Yes
IEC 60068-2-6 vibration
10 - 58 Hz: 0.075 mm
85 - 150 Hz: 1 g
1 octave/min, 20 sweeps
●
●
●
●
●
SCALANCE XB-100