5. DIP SWITCHES

1
MODE SWITCHES
SWITCH 1 – PROG (PAIR) – Pairing mode when ON and Normal operating mode when OFF
SWITCH 2 – SUPERVISED INPUTS – Supervised inputs active when ON
SWITCH 3 – COMMS LOSS BEACON – Pulses Alert Relay if ON, otherwise Relay is steady on
SWITCH 4 – Not used
SWITCH 5 – Not used
SWITCH 6 – Not used
2
RELAY OUTPUT SWITCH:
Relay Output Switch - not used in XRE-100 to XRE-100 Relay Extension operation.
3
PROGRAM/TEST BUTTON:
Program/Test Button - used with MODE SWITCH 1 to field pair units as described above. Functions as a TEST
TRANSMIT button during normal operation. When pressed, the XRE-100 will send a radio test packet and the RED
TRANSMIT LED will illuminate. If the paired XRE-100 is online, it will acknowledge with a radio test packet –
indicated by a momentary GREEN RECEIVE LED.
4
RELAY DELAY POTENTIOMETER:
Relay Delay Potentiometer: not used in XRE-100 to XRE-100 Relay Extension operation.