26/32 Table 7. Electro Oil Sterling 40 Burner (See Fig. 23)
Fuel
Nozzle
28 Sec. Kerosene
0.85 80°EH
28 Sec. Kerosene
0.85 80°EH
28 Sec. Kerosene
1.00 80°EH
32/50 Table 8. Electro Oil Sterling 50 Burner (See Fig. 23)
Fuel
Nozzle
28 Sec. Kerosene*
1.00 60°ES
28 Sec. Kerosene*
1.25 60°S
28 Sec. Kerosene*
1.65 60°S
35 Sec. Gas Oil*
0.65 80°S
35 Sec. Gas Oil*
0.85 60°S
35 Sec. Gas Oil*
1.10 60°S
50/70 Table 9. Electro Oil Inter B20B Burner (See Fig. 24)
Fuel
Nozzle
28 Sec. Kerosene*
1.35 60°S
28 Sec. Kerosene*
1.75 60°S
~28 Sec. Kerosene*
2.00 60°S
35 Sec. Gas Oil*
1.00 60°S
35 Sec. Gas Oil*
1.35 60°S
~35 Sec. Gas Oil*
1.75 60°S
* NOTE: For use on conventional flue only.
** NOTE: The flue gas temperature is measured in the gas sampling hole on the flue outlet plate. The probe should be inserted to a depth of 50mm and angled towards the flue outlet.
The temperature measured is not an absolute flue gas temperature and is for general guidance purposes only!
NOTE: The pump pressure given is for general guidance only as variations in nozzle output can be up to ± 15%. It is, therefore, essential that the air is adjusted to give the correct CO
NOTE: The nozzle type used on 28 Sec. Kerosene outputs are nozzles calibrated specifically for use with 28 Sec. Kerosene which gives less variation in nozzle output than the standard
35 Sec. Gas Oil nozzles. However, if a 28 Sec. Kerosene nozzle is not available at servicing or commissioning it is appropriate to install a 35 Sec. Gas Oil nozzle providing the output, spray
angle and pattern of the nozzle is the same as the 28 Sec. Kerosene nozzle (e.g. 0.75 80°EH may be replaced with a 0.75 80°H).
~NOTE: At 70kW the air guide should be removed (See Fig. 24)
NOMINAL BOILER RATING AT NORMAL OPERATING TEMPERATURE
Pump
Fuel Flow
Pressure
Rate
(p.s.i.)
Kg/h
l/h
110
2.36
2.99
130
2.66
3.37
130
2.95
3.74
NOMINAL BOILER RATING AT NORMAL OPERATING TEMPERATURE
Pump
Fuel Flow
Pressure
Rate
(p.s.i.)
Kg/h
l/h
130
2.90
3.67
130
3.78
4.78
115
4.64
5.87
185
2.95
3.47
200
3.83
4.51
185
4.71
5.54
NOMINAL BOILER RATING AT NORMAL OPERATING TEMPERATURE
Pump
Fuel Flow
Pressure
Rate
(p.s.i.)
Kg/h
l/h
165
4.62
5.85
155
5.55
7.03
145
6.47
8.19
240
4.69
5.52
180
5.63
6.62
160
6.57
7.73
Flue Gas
Approx.
%CO
Temp.
2
(°C)**
Setting
225
11.0-11.5
240
11.0-11.5
245
11.5-12.0
Flue Gas
Approx.
%CO
Temp.
Air
2
(°C)**
Setting
185
11.5-12.0
7.50
200
12.0-12.5
14.25
230
12.0-12.5
23.50
190
11.0-11.5
8.75
205
11.0-11.5
17.00
235
12.0-12.5
25.00
Flue Gas
Approx.
%CO
Temp.
2
(°C)**
Setting
205
11.5-12.0
225
12.0-12.5
235
12.0-12.5
4.5
205
11.0-11.5
225
12.0-12.5
235
12.0-12.5
4.5
5
RS Balanced Flue Appliance
Appliance
Air
Input
kW
Btu/hr
10
28.5
97,000
15
32
109,000
20
35.5
121,000
Conventional Flue Appliance (CF)
Appliance
Input
kW
Btu/hr
35
119,000
45
155,000
56
191,000
35
119,000
45
155,000
56
191,000
Conventional Flue Appliance (CF)
Appliance
Air
Input
kW
Btu/hr
3
55.5
190,000
4
67
229,000
78
268,000
3
55.5
190,000
4
67
229,000
78
268,000
Output
kW
Btu/hr
26
89,000
29
99,000
32
109,000
Output
kW
Btu/hr
32
109,000
41
140,000
50
171,000
32
109,000
41
140,000
50
171,000
Output
kW
Btu/hr
50
171,000
60
205,000
70
239,000
50
171,000
60
205,000
70
239,000
value.