AUSTRALIAN MONITOR DIGIPAGE Installation And Operation Manual
AUSTRALIAN MONITOR DIGIPAGE Installation And Operation Manual

AUSTRALIAN MONITOR DIGIPAGE Installation And Operation Manual

Multizone paging and source selection system
Hide thumbs Also See for DIGIPAGE:

Advertisement

INSTALLATION AND OPERATION MANUAL
DIGIPAGE
MULTIZONE PAGING AND SOURCE SELECTION SYSTEM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DIGIPAGE and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for AUSTRALIAN MONITOR DIGIPAGE

  • Page 1 INSTALLATION AND OPERATION MANUAL DIGIPAGE MULTIZONE PAGING AND SOURCE SELECTION SYSTEM...
  • Page 2: Important Safety Information

    Respecter les polarités des terminaux ainsi que le speaker wiring during normal operation. câblage des enceintes pendant le fonctionnement afin d’assurer une utilisation sécurisee. PAGE 2 DIGIPAGE MULTIZONE PAGING AND SOURCE SELECTION SYSTEM INSTALLATION AND OPERATION MANUAL...
  • Page 3 LED, the DigiPage provides extensive status indication to the user. SETUP The DigiPage is also expandable to 16 zones via a simple link cable to a second TROUBLESHOOTING unit. Paging stations are available in 8 zone and 16 Zone models allowing paging into any individual zone, any combination of zones or All Call.
  • Page 4: Front Panel

    FRONT PANEL Expanded view PAGE 4 DIGIPAGE MULTIZONE PAGING AND SOURCE SELECTION SYSTEM INSTALLATION AND OPERATION MANUAL...
  • Page 5 This switches power from the power supply (included). NOTE: When 24VDC emergency power is supplied, the unit is on regardless of the switch position DIGIPAGE MULTIZONE PAGING AND SOURCE SELECTION SYSTEM INSTALLATION AND OPERATION MANUAL PAGE 5...
  • Page 6: Rear Panel

    REAR PANEL PAGE 6 DIGIPAGE MULTIZONE PAGING AND SOURCE SELECTION SYSTEM INSTALLATION AND OPERATION MANUAL...
  • Page 7 In a Master/Slave configuration, these also control TONE GEN OUTPUT LEVEL This recessed program linked inputs. (see Linking Section) trim pot controls the output level of the tones and the chime. DIGIPAGE MULTIZONE PAGING AND SOURCE SELECTION SYSTEM INSTALLATION AND OPERATION MANUAL PAGE 7...
  • Page 8: Installation

    OVERVIEW The DigiPage features extensive flexibility in the range of input sources that it can accommodate. In addition, the zone outputs may be used to feed power (booster) amplifiers, mixers, mixer amplifiers etc. It is therefore important to think about the interfacing of the DigiPage with the other equipment if optimum performance is to be achieved.
  • Page 9: Cat5 Termination

    NOTE: CAT5 cable consists of four pairs of wires: it is not sufficient to simply wire the two ends pin for pin, ignoring pairing. Power Requirements The DigiPage can operate from the plug pack supplied and/or a separate 24V DC power supply. A NOTE ABOUT GROUNDING: It may be necessary in some circumstances to ground the DigiPage to eliminate noise in the system.
  • Page 10 Pre-Announce Chime & Adding More Paging Stations & DPRMs The only internal setup that is available in the DigiPage is for the configuration of the chime tone that sounds in each zone. The unit comes shipped with the The maximum distances quoted in the Table #1 are due to DC current chime enabled in all zones.
  • Page 11 DIMENSIONS FRONT PANEL REAR PANEL SIDE PANEL DIGIPAGE MULTIZONE PAGING AND SOURCE SELECTION SYSTEM INSTALLATION AND OPERATION MANUAL PAGE 11...
  • Page 12 Select PROG TEST in all other zones. When the DigiPage was shipped to you from the factory it was set up in a particular way. In the following procedure it is essential that you are starting Bring up the MASTER volume in all other zones and check for from these initial settings.
  • Page 13: Troubleshooting

    - Check Remote Panel with good cable at DigiPage Busy LED on Another device has control of the zone - Check other units - Cycle power if suspect system lock-up DIGIPAGE MULTIZONE PAGING AND SOURCE SELECTION SYSTEM INSTALLATION AND OPERATION MANUAL PAGE 13...
  • Page 14: Linking Two Digipage Systems

    LINKING TWO DIGIPAGE SYSTEMS DigiPage is fully expandable to form a 16 zone paging system by the simple linking of two units. One DigiPage is then designated the master unit, driving zones 1-8, with the slave unit driving zones 9-16. The following settings and connections are required to form a linked DigiPage system.
  • Page 15: Operation

    Remembering Settings / Powering Up And Down: The output level is controlled by a digital up/down switch arrangement. The DigiPage is designed to remember it’s last setting when powering down. There are 32 levels from off to maximum in a non linear audio configuration.
  • Page 16: Paging Station

    All Call to all zones. LED indicators provide the user with visual feedback of the zones being paged or if the zone selected is busy. Ample label space is provided on the Paging Station, which also provides a microphone gain control. Connection to the DigiPage is via low cost CAT 5 cable and as with all Australian Monitor installation products, the Paging Station provides an elegant solution at a contractor friendly price.
  • Page 17: Installation And Setup

    Terminating In an RS485 network (of which the DigiPage is part of) it is important to terminate the last device in each CAT5 RUN. Two jumpers are provided for the data transmission and the voice transmission to be terminated if that Paging Station is at the end of a CAT5 RUN (see diagram).Shipped...
  • Page 18: Remote Control Panel

    Selection System. The DPRM allows control over program source selection, local input selection and volume control from a remote location. LED illumination provides the user with visual feed back if the system is busy. Connection to the DigiPage is via low cost CAT 5 cable and as with all Australian Monitor Installation products, the Remote Control Panel provides an elegant solution at a contractor friendly price.
  • Page 19 DigiPage unit. There are two holes available adjacent to the terminal block for securing the CAT5 cable with a cable tie. DIGIPAGE MULTIZONE PAGING AND SOURCE SELECTION SYSTEM INSTALLATION AND OPERATION MANUAL PAGE 19...
  • Page 20: Block Diagram

    BLOCK DIAGRAM PAGE 20 DIGIPAGE MULTIZONE PAGING AND SOURCE SELECTION SYSTEM INSTALLATION AND OPERATION MANUAL...
  • Page 21 WHITE Cat No. DPRIPW REMOTE CONTROL PANELS STANDOFF SURFACE MOUNT BOX BLACK Cat No. DPRMB BLACK Cat No. DPRMSMBB WHITE Cat No. DPRMW WHITE Cat No. DPRMSMBW DIGIPAGE MULTIZONE PAGING AND SOURCE SELECTION SYSTEM INSTALLATION AND OPERATION MANUAL PAGE 21...
  • Page 22: Specifications

    SHIPPING DIMENSIONS (W x D x H) 537mm x 255mm x 258mm (21.1” x 10” x 10.2”) WEIGHT Net Weight 6kg (13.2lb) Shipping Weight 7.6kg (16.8lb) All measurements are reference to 1.5V (+6dBu) PAGE 22 DIGIPAGE MULTIZONE PAGING AND SOURCE SELECTION SYSTEM INSTALLATION AND OPERATION MANUAL...
  • Page 23 NOTES DIGIPAGE MULTIZONE PAGING AND SOURCE SELECTION SYSTEM INSTALLATION AND OPERATION MANUAL PAGE 23...
  • Page 24 ENGINEERED BY AUSTRALIAN MONITOR Address: Level 7, 130 Pitt Street, Sydney NSW 2000 Australia. Website: www.australianmonitor.com.au International enquiries email: international@australianmonitor.com.au...

Table of Contents