Installation - H3C UniServer R6900 G3 Operating System Installation Manual

Hide thumbs Also See for UniServer R6900 G3:
Table of Contents

Advertisement

b. Install smartpqi (v1.02), and then reboot the server.
c. Install aacraid (v52011) to replace aacraid provided with the storage controller.
d. Add rdblacklist=aacraid to /etc/grub2-efi.cfg, and then reboot the server.
e. Execute the lspci -vvs b3:00.0 command to verify that the drive in use is smartpqi.
Figure 170 Verifying the drive in use
f. If the issue persists, contact H3C Support.
To resolve the issue for an SUSE OS, update the smartpqi and aacraid drivers and then
reboot the server.
SUSE12SP2 OS installation in Legacy and UEFI
modes takes a long time and the webpage is stuck
after installation
Symptom
SUSE12SP2 OS installation in Legacy and UEFI modes takes a long time and the webpage is stuck
after installation if you use HBA-1000-M2-1 to set up RAID.
Solution
To resolve the issue:
1.
Upgrade HBA-1000-M2-1 to FW 3.02.
2.
Add kernel boot parameter linux dd when starting to install the OS.
3.
Update the aacraid driver for SUSE12SP2 before you install the OS.
4.
If the issue persists, contact H3C Support.