Hbh072-120 Dimensional Data - Heat Controller HBH Series Engineering Design Manual

Commercial horizontal packaged water source heat pump, 6-10 tons
Table of Contents

Advertisement

Engineering Design Guide
LEFT RETURN STRAIGHT DISCHARGE
CAP
CAP
FRONT
NOTES:
-
1. Access is required for all removable panels and installer should take care to comply with all building codes and allow
2. Water inlet and water outlet connections are available on either side (left or right) of the unit. Qty (2x) MPT Plugs are
3. Condensate drain is available on end opposite compressor.
4. Electrical access is available on either side (left or right) of the front.
5. Electric box is on right side. It can be field converted to left side. Conversion should only be attempted by qualified
7. Overall cabinet width dimensions does not include filter rail and duct flange.
4.3"
[10.8cm]
U
T
1.3"
[3.3cm]
condensate
BSP
F
G

HBH072-120 Dimensional Data

Overall Cabinet
A
B
C
Model
Width
Depth
Height
in.
36.3
84.9
21.6
072-120
cm.
92.2
215.6
54.9
ALL CONFIGURATIONS REQUIRE SERVICE ACCESS AREA
DESCRIBED IN NOTES 5 AND 6.
BSP
A
B
F
D
E
G
EAP
O
CBP
CAP=Compressor Access Panel
M
CBP=Control Box Panel
P Q
BSP=Blower Service Panel
R
EAP=Expansion Valve Access panel
K
1=Water Outlet 1-1/4" FPT (072-096) 1-1/2" FPT (120)
2=Water Inlet 1-1/4" FPT (072-096) 1-1/2" FPT (120)
3=Condensate 3/4" FPT
4=High Voltage 1-1/8" [2.9cm] KO
5=Low Voltage 7/8" [2.2cm] KO
All dimensions in table are inches (cm).
adequate clearance for future field service.
shipped loose in a plastic bag tied to the water leg in front of the unit. Installer must plug water inlet/outlet side not being
connected to.
service technician. If electric box relocated to opposite side, and water connected to opposite side, then this access is
not required.
87"
HANGER BRACKET DIMENSIONS
[221cm]
CONTROL BOX
1.0"
[2.54cm]
PLAN VIEW
34.1"
TOP
[86.6cm]
S
V
LEFT RETURN LEFT VIEW-
AIR COIL SIDE
LEFT RETURN END DISCHARGE
CAP
CBP
FRONT
EAP
CAP
E
D
Discharge Connections
Duct Flange
D
E
F
G
Supply
Supply
Supply
Depth
Width
Height
14.0
17.0
13.5
7.8
35.6
43.2
34.3
19.8
HBH SERIES
RIGHT RETURN STRAIGHT DISCHARGE
BSP
Note 6
C
1
EAP
2
LEGEND
Note 6
PLAN VIEW
TOP
CONTROL BOX
V
S
RIGHT RETURN RIGHT VIEW-
AIR COIL SIDE
condensate drain
RIGHT RETURN END DISCHARGE
CAP
FRONT
CBP
Water Connections
Electrical Knockouts
K
L
M
O
1
2
Water
Water
Outlet
Inlet
15.0
8.3
4.0
2.0
38.1
21.1
10.2
5.1
19
Heat Controller, Inc.
HBH072-120 Dimensional Data
CBP
1
5
4
Note 5, 6
CAP
2
CAP
FRONT
SERVICE ACCESS
Note 6
3
U
1.3"
[3.3cm]
CAP
EAP
BSP
Return Air Connections
Using Return Air Opening
P
Q
R
S
T
Return
Return
Depth
Height
18.8
16.8
13.8
65.0
18.0
47.8
42.7
35.1
165.1
45.7
U
V
1.0
18.9
2.5
48.0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hbh096Hbh120Hbh072