Bradford White GX225S BN Series Service Manual page 5

Atmospheric gas water heaters

Advertisement

LED Status
Five flashes and a three
Thermowell fault
second pause.
Seven flashes and a
Gas control fault detected.
three second pause.
Eight flashes and a three
Pilot flame remains on while gas control is in
second pause.
the "OFF" position.
Troubleshooting Chart (cont.)
For Models Using Honeywell Gas Control
Control Status
Probable Cause
1. Damage to thermowell
wires.
2. Thermowell sensor resistance
out of range.
1. Gas control needs to be reset.
2. Gas control is wet or physically
damaged.
Pilot valve stuck in the open position.
Page 5
Service
Procedure
See Service Procedure
AG-III, Page 16
Lite pilot per the instructions
located on the lighting
instructions label or the
lighting instructions located in
the installation and operation
manual.
Replace gas control.
See Service Procedure
AG-III, Page 18.
5