Download Print this page

Bradford White GX225S BN Series Service Manual page 18

Atmospheric gas water heaters

Advertisement

HONEYWELL GAS CONTROL & THERMOWELL REMOVAL
Step 1. Turn the gas control knob to the "OFF" position.
Step 2. Turn off water supply and drain water heater completely.
Step 3. Turn off and disconnect gas supply to control
Step 4. Disconnect wire harness and burner
assembly from the gas control.
Step 5. Remove gas control and thermowell by rotating flats of the thermowell counter clockwise.
HONEYWELL GAS CONTROL REMOVAL FROM THERMOWELL
NOTE; Following the instructions below allows the removal of the gas control from the thermowell without
removing the thermowell from the tank.
Step 1. Turn the gas control knob to the "OFF" position.
Step 2. Turn off and disconnect gas supply piping to the gas control.
Step 3. Disconnect wire harnesses and burner assembly from the gas control.
Step 4. Using the gas control service tool (part number 239-45991-00) available from your Bradford White
parts supplier, insert tool into the back of the gas control (see Figure 32 & 33).
Insert tool into
back of gas
control
Step 5. Pivot service tool towards water heater as far as possible (see Figure 34). Lift up straight on gas
control. The gas control should move about 1/8". Hold gas control in position and remove tool.
Lift straight up on the gas control to remove completely from the thermowell.
18
Figure 32
Figure 34
Page 18
SERVICE PROCEDURE AG-III
Honeywell Gas Control and Thermowell
Replacement
Gas Control
Figure 31
View from back of
gas control for clarity
Figure 33
Thermowell