  • Page 1 AUTOFOG ™ MLVH-10A Owners Manual...
  • Page 2: Table Of Contents

    Cleaning & Maintenance.......................................13 Assembly Diagram ........................................14 Assembly Parts List........................................15 Compressor Plumbing Diagram ..................................16 Compressor Plumbing Parts List..................................17 Compressor Diagram ......................................18 Compressor Parts List......................................19 Nozzle Assembly Parts List....................................20 Troubleshooting........................................21-22 Notes ..............................................23 MLVH-MAN3 Dramm Autofog MLVH-10A Manual Printed in the U.S.A. Revised 10/2016...
  • Page 3: Warning

    WARNING The Dramm Mini Autofog MLVH-10A sprays dangerous toxic chemicals. Please read and understand the following safety precautions before operating your Autofog. Failure to follow these instructions may result in serious injury or death. •Do Not Use This Machine In An •...
  • Page 4: Assembly Instructions

    Rotate the tank so that the small suction hole faces the quality of the spray pattern and pressure gauge front of the machine (the control panel end is the back readings. If you have any questions, contact the Dramm of the machine). Corporation Service Department at 800-258-0848 or 920-684-0227.
  • Page 5: How Does My Autofog Work

    Note: Dramm offers an instructional video on our website. Please watch this before using your machine. How Does My Autofog MLVH-10A Work? The Dramm Autofog applys chemicals under the low-volume (LV) principle. This means that the same amount of active chemical is applied to a given area, but the chemical is diluted into reduced amounts of water.
  • Page 6: Pre-Operation Checklist

    If you plan to use oxidizers in your Autofog, piping when the pressure is too low. Eliminate CONTACT DRAMM BEFORE THE FIRST USE OF YOUR clogs if the pressure is too high. Pressure readings MACHINE to purchase a stainless steel nozzle at a reduced cost.
  • Page 7: Chemical Mixture And Application

    5,000 square feet, make the rate calculation for 5,000 square feet and reduce that 3. Greenhouse growers apply from 25 to 300 gallons of amount proportionately. Contact the Dramm Service spray concentrate per 10,000 square feet, the average Department at 800-258-0848 or 920-684-0227 if you high volume application is 40 - 50 gallons per 10,000 have any questions.
  • Page 8: Low Rate Calculations

    A ratio of 10 to 1 for Emulsifiable Concentrates. should be followed. E.C. = Emulsifiable Concentrate F. = Flowable W.P. = Wettable Powder Make Your LOW RATE Calculations Below. Dramm Autofog MLVH-10A Manual...
  • Page 9: High Rate Calculations

    Flowables. A ratio of 10 to 1 for Emulsifiable chemical you intend to use, the labeled rate Concentrates. should be followed. E.C. = Emulsifiable Concentrate F. = Flowable W.P. = Wettable Powder Make Your HIGH RATE Calculations Below. Dramm Autofog MLVH-10A Manual...
  • Page 10: Spraying Procedure/Timer Settings

    Follow all EPA Guidelines for re-entry. DISCHARGE TIMES FOR MLVH-10A Clear Water Time 1.0 liter 30 minutes 2.0 liters 1 hour 3.0 liters 1.5 hours 4.0 liters 2.0 hours 5.0 liters 2.5 hours 6.0 liters 3.0 hours 7.0 liters 3.5 hours Dramm Autofog MLVH-10A Manual...
  • Page 11: Cleaning & Maintenance

    O-ring for damage or wear. cleaning procedure for the MLVH is available on our website. NOTE: This procedure is necessary after every application of wettable powder solutions. Be sure to remove the nozzle cap and clean the nozzle. Dramm Autofog MLVH-10A Manual...
  • Page 12: Assembly Diagram

    MLVH-10A Assembly Diagram Dramm Autofog MLVH-10A Manual...
  • Page 13: Assembly Parts List

    MLVH-10A Assembly Parts List MLVH-10A Accessories Part # Description Qty. 500926M Graduated Cylindar Funnel LVM100 Funnel 153582 Strainer these items do not appear in the diagram. Dramm Autofog MLVH-10A Manual...
  • Page 14: Compressor Plumbing Diagram

    MLVH-10A Compressor Plumbing Dramm Autofog MLVH-10A Manual...
  • Page 15: Compressor Plumbing Parts List

    MLVH-10A Compressor Plumbing Parts List Dramm Autofog MLVH-10A Manual...
  • Page 16: Compressor Diagram

    MLVH-10A Compressor Diagram Dramm Autofog MLVH-10A Manual...
  • Page 17: Compressor Parts List

    MLVH-10A Compressor Parts List Dramm Autofog MLVH-10A Manual...
  • Page 18: Nozzle Assembly Parts List

    Part # Component # Description Qty. D7513670000A Nozzle Assembly 7010 Nozzle Base 7020 7030 Lock Nut 7100 Extension Pipe D10151 Stainless Suction Tube 7020 7460 Fits Inside 741A 7040 741A 7010 7460 7030 7440 7450 7100 Dramm Autofog MLVH-10A Manual...
  • Page 19: Troubleshooting

    Inspect the entire In most cases the sleeve must be replaced if it is suction tube for clogging. damaged, dented, bent or cracked. DO NOT OVER TIGHTEN NUT Suction Tube Sleeve Continued on the next page... Dramm Autofog MLVH-10A Manual...
  • Page 20 4. Pressure gauge reads too high. A. Piping is clogged. Check the entire piping for obstructions and replace any defective or clogged sections. B. A clogged nozzle or nozzle cap will cause Dramm Autofog MLVH-10A Manual...