Model Gpc-5000-Rp-S Series Control Cabinet - GAYLORD CG Series Technical Manual

Water-wash ventilators with model c-5000 command center
Table of Contents

Advertisement

MODEL GPC-5000-RP-S SERIES CONTROL CABINET

This Control Cabinet Is Used When Ventilators Are Washed In Sequence Groups.
COMMAND CENTER
MODEL
C-5000-S-TC
OPERATING INSTRUCTIONS
1 . P u s h " S t a r t
F a n " b e f o r e
t u r n i n g
o n c o o k i n g
e q u i p m e n t .
2 . A t t h e e n d o f t h e d a y , o r w h e n e v e r
c o o k i n g i s c o m -
p l e t e d ,
p u s h " S t a r t
W a s h " .
T h i s w i l l t u r n o f f t h e e x h a u s t
f a n
a n d b e g i n a t i m e d w a s h c y c l e . NOTE: 2 4 h o u r k i t c h e n s
m u s t p u s h " S t a r t
W a s h " a t l e a s t o n c e a d a y o r a s n e e d e d
f o r
p r o p e r
c l e a n i n g .
3 . T o s e t t h e l e n g t h
o f t i m e f o r t h e w a s h c y c l e ,
o p e n t h i s
c a b i n e t
d o o r a n d s e t t h e t o g g l e
s w i t c h e s
f o r e i t h e r
" L i g h t -
d u t y " , " M e d i u m "
o r " H e a v y - d u t y "
c o o k i n g
e q u i p m e n t .
E x t r e m e
c o o k i n g
l o a d s m a y r e q u i r e
m o r e t h a n o n e w a s h
c y c l e p e r d a y .
NOTE: I f t h e C o m m a n d
C e n t e r
i s a " S " , " T C " o r " R S P C "
S e r i e s ,
r e f e r t o a d d i t i o n a l
o p e r a t i n g
i n s t r u c t i o n s
i n s i d e
t h i s p a n e l .
FAN ON
FIRE
WASH ON
START
START
FAN
WASH
LOW DETERGENT
1 . I f " W a s h O n " l i g h t f l a s h e s
d e t e r g e n t
i s l o w .
FIRE CONDITION
1 . A f l a s h i n g
f i r e l i g h t
i n d i c a t e s
t h e c o n t r o l
i s i n a n External Fire
Mode - e x h a u s t
f a n o n , f i r e d a m p e r
o p e n , a n d w a t e r w a s h
n o z z l e s
o n .
2 . A s o l i d f i r e l i g h t i n d i c a t e s
t h e c o n t r o l
i s i n a n Internal Fire
Mode - e x h a u s t
f a n o f f , f i r e d a m p e r
c l o s e d ,
a n d w a t e r w a s h
n o z z l e s
o n .
GAYLORD INDUSTRIES, INC.
A Subsidiary
of
Gaylord
International,
Inc.
TUALATIN,
OR 97062-8549
PC.
NO.
1.
Solenoid Valve ..............................................................
A. Replacement Coil (120 Volt) ...............................
B. Solenoid Valve Repair Kit ........... Pipe Size: 1/2"
.................................................... Pipe Size: 3/4"
....................................................... Pipe Size: 1"
................................................. Pipe Size: 1-1/4"
................................................. Pipe Size: 1-1/2"
2.
Detergent Tank (2 Gallon) ............................................
3.
Pressure / Temperature Gauge ....................................
4.
Brass Check Valve .......................................................
5.
FS-4 Series Flow Switch (Optional) ..............................
6.
Detergent Pump ........................................... (120 Volt)
............................................................ (220 Volt)
............................................................................
7.
Command Center Model C-5000 ..................................
8.
Backflow Preventor "RP" Device Type .........................
DESCRIPTION
(220 Volt) .............................
28
MODEL "GPC-5000-RP-S" SERIES
CONTROL CABINET
GAYLORD
MFG. PART NO.
PART NO.
171N-
(Specify Size)
10156
238210032D
10157
238210058D
14387
310-387
14388
310-388
14389
310-420
14390
310-506
14391
310-421
10221
T-3
10175
HPT30L
10264
VF-038D
16892
122340
10222
VF-100P 60B
10223
VF-100P 60B1
(Refer to Page 32)
(Refer to Page 30)
009-QT
(Specify Size)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rg series

Table of Contents