Electronic Position Indicators - Agilent Technologies 8710 Series Operating And Service Manual

Coaxial multiport switches
Table of Contents

Advertisement

Electronic Position Indicators

Agilent 8710x Operating and Service Manual
Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com
The electronic position indicators consist of optically isolated, solid
state relays which are driven by photo- electric sensors coupled to
the mechanical position of the RF path's moving elements (See
Figure
3). The circuitry consists of a common which can be
connected to an output corresponding to each RF path. If multiple
RF paths engaged, the position indicator corresponding to each
closed RF path will be connected to common. The solid state
relays are configured for AC and/or DC operation. See page 21 for
"Indicator
Specifications". The electronic position indicators
require that the supply (20 to 32 VDC) be connected to pin 1 and
ground connected to pin 15.
* Path 1 and 4 are not connected for 87104A/B/C/D
Figure 3
Pin Configuration for Indicator Function
Switch Configuration
PIN NUMBER
FUNCTION
2
COMMON
*
4
PATH 1
6
PATH 2
8
PATH 3
10
*
PATH 4
12
PATH 5
14
PATH 6
2
15