6.3.5.

Terminating resistor requirement (CAN communication)

Two terminating resistors (120 Ohm) are required on the CAN bus for proper operation (one at each end of the
CAN bus). Only two terminating resistors are allowed on a CAN bus.
Terminating resistor
CAN 3-way "Y" connector

6.4. Communication compatibility with Class 1 products

The ITL40 display is compatible with other Class 1 CAN and 1-wire products.
6.4.1.

1-wire compatibility

An ITL40 display configured with 1-wire communication is compatible with...
4 light remote driver module (p/n 106877)
Pump input sensor module (p/n 111097)
Mini remote driver module (p/n 112648)
Mini remote dash gauge (p/n 112649)
4 and 5 light ITL displays (p/n 106299, 106296, 108858, 108859, 113739, 114378, 114005, 114379)
6.4.2.

CAN compatibility

An ITL40 display configured with CAN communications is compatible with...
Command Master (p/n 111084, 111085, 111086)
Pump input sensor module (p/n 111097)
4 and 5 light ITL displays (p/n 113739, 114378, 114005, 114379)
MANUAL P/N:118253
S U I T A B L E F O R E X T E R N A L D I S T R I B U T I O N
OPERATION MANUAL
ITL40
P/N
Intelli-Tank Level 40
p/n DT06-3S-P006
p/n DT04-3P-P007
118404-XX
23 of 27
PAGE
DATE
6/12/2019
REV
1.30
BY
AMS
P
: 6/12/19
RINTED

Advertisement

Table of Contents
loading

Table of Contents