FORM-ENG-0018 REV A 05-27-03
607 NW 27th Ave
PRODUCT GROUP
Ocala, FL 34475
Ph: 352-629-5020 or 1-800-533-3569
Fax : 352-629-2902 or 1-800-520-3473
PRODUCT
6.3.5.
Terminating resistor requirement (CAN communication)
Two terminating resistors (120 Ohm) are required on the CAN bus for proper operation (one at each end of the
CAN bus). Only two terminating resistors are allowed on a CAN bus.
Terminating resistor
CAN 3-way "Y" connector
6.4. Communication compatibility with Class 1 products
The ITL40 display is compatible with other Class 1 CAN and 1-wire products.
6.4.1.
1-wire compatibility
An ITL40 display configured with 1-wire communication is compatible with...
•
4 light remote driver module (p/n 106877)
•
Pump input sensor module (p/n 111097)
•
Mini remote driver module (p/n 112648)
•
Mini remote dash gauge (p/n 112649)
•
4 and 5 light ITL displays (p/n 106299, 106296, 108858, 108859, 113739, 114378, 114005, 114379)
6.4.2.
CAN compatibility
An ITL40 display configured with CAN communications is compatible with...
•
Command Master (p/n 111084, 111085, 111086)
•
Pump input sensor module (p/n 111097)
•
4 and 5 light ITL displays (p/n 113739, 114378, 114005, 114379)
MANUAL P/N:118253
S U I T A B L E F O R E X T E R N A L D I S T R I B U T I O N
OPERATION MANUAL
ITL40
P/N
Intelli-Tank Level 40
p/n DT06-3S-P006
p/n DT04-3P-P007
118404-XX
23 of 27
PAGE
DATE
6/12/2019
REV
1.30
BY
AMS
P
: 6/12/19
RINTED